Abstract:
This study evaluated whether half-acquisition (180° scan) pediatric cone-beam computed tomography (CBCT; 3D Accuitomo F17, J. Morita, Kyoto, Japan) reduces radiation exposure while maintaining sufficient diagnostic image quality for identifying ectopic eruptions and impacted teeth. Additionally, it was investigated whether a low-noise reconstruction filter (G_101) mitigates image quality degradation in 180° scans. Three board-certified oral and maxillofacial radiologists certified by the Japanese Society for Oral and Maxillofacial Radiology visually evaluated clinical images from 12 pediatric patients (aged 6-10 years). The image quality was objectively assessed using phantom-based analyses of the modulation transfer function (MTF), noise power spectrum (NPS), and comprehensive objective image quality calculated from MTF and NPS values. Although 180° images showed increased noise and slightly lower visual assessment scores compared with 360° images, they remained diagnostically acceptable. In 180° reconstructions, the median visual scores with the G_101 filter were slightly higher than those with the standard G_001 filter, with small differences (within approximately 0-3 points on a 100-point scale), although the differences were not statistically significant. Interestingly, in approximately 28% of 180 evaluations, 180° images scored higher than 360° images, likely due to reduced motion artefacts from shorter acquisition. In a previous phantom experiment, the dose area product (DAP) for 360° and 180° scans was 490 mGy cm2 and 249 mGy cm2, respectively, indicating that 180° scan reduces radiation exposure while maintaining clinically acceptable image quality. These findings suggest that half-acquisition, when combined with an appropriate reconstruction filter, may offer a practical, low-dose alternative for pediatric dental imaging.
More Related Videos
09:10Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
Published on: August 5, 2021
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET