Optimization of the Contrast Concentration for Low-Tube-Voltage Chest CT: A Randomized Controlled Trial with
Jiho Park1, Bo Mi Gil2, Yun-Hyeon Kim3
1Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 222, Banpo-daero, Seoul 06591, Republic of Korea.
Low-concentration contrast media (LCCMs) used with 100 kVp chest CT provide comparable image quality to standard protocols. This approach may reduce adverse reactions, enhancing patient safety in computed tomography (CT) imaging.
Area of Science:
- Radiology
- Medical Imaging
- Diagnostic Imaging
Background:
- Conventional chest CT protocols often utilize higher tube voltages and standard contrast media concentrations.
- Optimizing contrast media (CM) concentration and tube voltage is crucial for balancing image quality, radiation dose, and patient safety.
Purpose of the Study:
- To assess the non-inferiority of low-concentration contrast media (LCCMs) in 100 kVp chest CT compared to standard protocols.
- To evaluate the impact of varying CM concentrations on the quality of enhanced chest CT scans.
Main Methods:
- A prospective, multicenter, randomized controlled trial involving adult patients (BMI < 30).
- Participants were assigned to four groups: control (120 kVp, 320 mgI/mL CM) and three test groups (100 kVp with 320, 270, or 240 mgI/mL CM).
- Image quality was assessed by two independent readers, with non-inferiority based on the proportion of acceptable scans; adverse reactions were recorded.
Main Results:
- 100 kVp chest CT with LCCMs (270 and 240 mgI/mL) demonstrated non-inferior image quality compared to the standard protocol.
- While one reader noted a lower proportion of acceptable scans with 100 kVp and standard CM (320 mgI/mL), the other did not find significant inferiority.
- Adverse reactions like injection site pain and heat sensations were less frequent in LCCM groups, with systemic heat showing statistical significance (p = 0.003).
Conclusions:
- Low-tube-voltage (100 kVp) chest CT using LCCMs achieves non-inferior diagnostic image quality compared to standard protocols.
- Using conventional concentration CM with 100 kVp may decrease the proportion of diagnostically acceptable scans.
- LCCMs in conjunction with 100 kVp chest CT show potential for improved patient safety due to reduced adverse events.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography