Tip Discharge Evolution Characteristics and Mechanism Analysis via Optical-Electrical Sensors in Oil-Immersed
Zehao Chen1, Yong Qian1, Gehao Sheng1
1School of Electrical Engineering, Shanghai Jiao Tong University, Shanghai 201100, China.
Abstract:
Tip discharge in oil-immersed transformers poses a significant threat to insulation integrity. Conventional detection methods, such as gas and electrical analysis, are limited by slow response times or susceptibility to interference. Additionally, the lack of systematic comparisons between aged and fresh oil using multi-modal signal correlations hinders the development of accurate diagnostic strategies. To address this, a multi-modal sensing platform employing optical, UHF, and HFCT sensors, complemented by visual observation, was developed to investigate the evolution characteristics and mechanisms of tip discharge and to compare the detection effectiveness of these methods. Experimental results reveal that aged oil undergoes a novel four-stage evolution, where discharge signals first rise to a local peak, then experience suppression, followed by a dramatic surge, and finally decline slightly before breakdown. This process is governed by an "Impurity-Assisted Cumulative Breakdown Mechanism," driven by impurity bridge growth and space charge effects, with signal transitions from 'decoupling' to synchronization. The optical sensor demonstrated superior sensitivity in early discharge stages compared to electrical methods. In contrast, fresh oil exhibited a "High-Field-Driven Stochastic Breakdown Mechanism," with isolated pulses from micro-bubble discharges maintaining a metastable state until a critical threshold triggers instantaneous failure. This study enhances the understanding of how oil condition alters discharge mechanisms and underscores the value of multi-modal sensing for insulation condition assessment.
More Related Videos
Related Concept Videos
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Instrument Transformers
Directional Relays
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...