Comparative Study of Simulation of Temperature Rise in Ring Main Unit
Published on: July 5, 2024
A VHF-Voltage Double Time Integral Method for Apparent-Charge Estimation of Partial Discharge in Gas-Insulated
Subin Gao1, Xiaoli Zhou1, Chao Pan2
1College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China.
Abstract:
Gas-insulated switchgear (GIS) is widely used in modern power systems, but transportation, installation, and manufacturing defects can trigger partial discharge (PD). Apparent charge is a key indicator of PD intensity and insulation deterioration, yet conventional pulse current measurements perform poorly in field environments because of interference, pulse superposition, non-flat sensor responses, and impedance mismatch. Very-high-frequency (VHF) sensing is sensitive to on-site PD but lacks a direct quantitative mapping to apparent charge. This study derives and optimizes a double time integral of voltage (DTIV) method for capacitively coupled VHF sensors. Simulation and experimental platforms were established, and through-origin linear regression was used to relate DTIV output to reference apparent charge. The first and second voltage zero-crossings (ZC1 and ZC2) were evaluated as integration upper limits, and the preferred DTIV_ZC2 strategy was further assessed using thresholds of 1% and 5% of the signal peak. For the simulated library, using the second zero-crossing increased the coefficient of determination from 0.8957 to 0.9585 and reduced the average relative error to 4.5%. A 5% threshold further improved these values to 0.9641 and 3.9%, respectively. The results support the feasibility of calibrated DTIV estimation for the tested sensor and ideal laboratory configuration.
Related Concept Videos
Power System Three-Phase Short Circuits
Ampere-Maxwell's Law: Problem-Solving
To solve the problem, we can use the equations from the analysis of an RC circuit and Maxwell's version of Ampère's law.
For the first part of the problem,...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Insulation Coordination