Background:
The marginal fit of dental restorations is a critical factor influencing their longevity and clinical success. With the advent of digital dentistry, intraoral scanning has emerged as an alternative to conventional impression techniques.
Methods:
This in vivo study included 20 patients requiring mandibular first molar crowns. A total of 40 crowns were fabricated and divided into two groups: Group A (n = 20) using conventional monophase impression technique and Group B (n = 20) using the digital impression technique. All teeth were prepared with a chamfer finish line. The marginal adaptation was evaluated using the silicone replica technique, and measurements were taken at four points (mid-buccal, mid-lingual, mid-mesial, and mid-distal) under a stereomicroscope.
Results:
The mean marginal discrepancy for Group A (conventional) was 107.69 ± 32.67 µm, while Group B (digital) showed a mean of 100.41 ± 35.53 µm. No statistically significant difference was found between the two groups (P = 0.504). Regional analysis also revealed no significant differences at any measurement point (buccal: P = 0.929; lingual: P = 0.866; mesial: P = 0.355; distal: P = 0.445). Both groups demonstrated marginal discrepancies within the clinically acceptable range of 120 µm.