Video-Based Automatic Quantification of Leg Edema: a Pilot Study in Patients With Hemodialysis With and Without Heart
Eiichiro Sato1, Nobuyuki Kagiyama1,2, Takatoshi Kasai1,2
1Department of Cardiovascular Biology and Medicine, Juntendo University Graduate School of Medicine Tokyo Japan.
Circulation Reports
|January 12, 2026
Summary
A new deep learning (DL) model uses videos to objectively assess pitting edema severity. This AI tool shows promise for improving patient care, especially in remote settings.
Area of Science:
- Medical Imaging
- Artificial Intelligence in Healthcare
- Clinical Diagnostics
Background:
- Pitting edema assessment is subjective and challenging, particularly in remote healthcare scenarios.
- Objective and reliable methods for grading edema severity are needed to improve patient management.
Purpose of the Study:
- To develop and evaluate a video-based deep learning (DL) model for objective classification of pitting edema severity.
- To address the subjectivity inherent in traditional edema assessment methods.
Main Methods:
- A convolutional neural network (EfficientNetB0) was trained on 247 videos of pretibial images from 34 hemodialysis patients.
- The model was trained to classify pitting edema on a 0-4 scale using pre- and post-pressing images.
Main Results:
- The DL model achieved 81.5% accuracy, 81.2% sensitivity, and 81.9% specificity in distinguishing severe edema (grades 3-4) from mild edema (grades 0-1).
- Accuracy reached 85.8% when differentiating extreme cases (grade 0 vs. grade 4).
Conclusions:
- This pilot study demonstrates the feasibility of using video-based DL for objective pitting edema detection.
- Further research with larger, diverse datasets and clinical validation is required for widespread implementation and generalization of the model.
Related Concept Videos
Hemodialysis II: Procedure and Complications
610
DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
610
Assessing Blood pressure in the Leg
8.7K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
8.7K