Related Experiment Video
Updated: Jan 14, 2026

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Device-measured capillary refill time identifies critically ill cases in the emergency department
Yayoi Miwa1, Satoshi Karasawa1, Takashi Shimazui1
1Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan.
None:
Capillary refill time (CRT) is a rapid, non-invasive indicator of tissue hypoperfusion and is associated with severity in critically ill patients. However, its clinical utility in the emergency department (ED) remains unclear, particularly when assessed using a quantitative device. We conducted a prospective, single-center observational study to evaluate whether device-measured CRT upon ED arrival is associated with clinical severity. One hundred nineteen adult patients transported to the ED by ambulance between August 2023 and October 2024 were enrolled. CRT was measured using the quantitative CRT device, and the average of three readings was analyzed. Critical illness was defined as an acute physiology and chronic health evaluation (APACHE) II score of ≥ 25. Among the participants, 27 (23%) had high APACHE II scores. CRT was significantly prolonged in this group (2.56 [1.84-3.36] vs. 1.67 [1.18-2.48] seconds, p = 0.0012) and showed a higher area under the receiver operating characteristic curve than lactate (AUC: CRT, 0.702; lactate, 0.669). CRT also demonstrated a weak but significant positive correlation with lactate levels (rs = 0.24, p = 0.0087) as well as a trend toward significant correlation with sequential organ failure assessment (SOFA) score (rs = 0.18, p = 0.051). These findings suggest that device-measured CRT is associated with clinical severity and may aid in the early identification of critically ill patients in emergency settings.
Related Concept Videos
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Coronary Syndrome III: Diagnostic Studies
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring pulse