Comparative Evaluation of Voxel-Level Dosimetry Methods in 90Y-Microsphere Radioembolization Using PET/CT
Hai Hu1,2,3,4, Zi-Wei Liang5, Ya-Bo Zhao1,2
1Center for Advanced Quantum Studies, School of Physics and Astronomy, Beijing Normal University, No. 19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
Abstract:
90Y-microsphere radioembolization is an established treatment for primary and metastatic liver cancer. Post-treatment PET/CT enables voxel-level absorbed dose estimation, but the optimal calculation method remains under evaluation. In this study, we compared three dosimetry approaches: Monte Carlo (MC), voxel S-value (VSV) method, and local energy deposition method (LDM). Post-treatment PET/CT data sets from 68 patients were analyzed (6 from the Deep Blue Data Repository and 62 from Beijing Tsinghua Changgung Hospital). MC dosimetry was implemented in GATE v9.0 and served as the reference standard. VSV was derived by convolving PET images with a precomputed 90Y voxel kernel, while LDM assumed complete local absorption of β-energy. Agreement with MC was assessed qualitatively using relative-difference maps, dose profiles, and isodose overlays, and quantitatively via voxelwise root-mean-square error (RMSE), Pearson correlation, Bland-Altman analysis of mean absorbed dose and equivalent uniform biological effective dose (EUBED), and absolute maximum deviations between cumulative and differential dose-volume histograms (DVHs) (1 Gy bins). MC simulations required ∼41 h per case, whereas the VSV kernel calculation required only one simulation with ∼6 h. Then VSV and LDM costed only a few seconds to obtain the dose images. VSV preserved MC isodose geometry and dose-profile shapes, while LDM overestimated doses in high-dose regions. At profile maxima, VSV's peak relative deviation was ∼1-3% versus ∼12-19% for LDM. Across patients, VSV achieved a voxelwise RMSE of 2.21% and <3% differences in mean dose and EUBED, with tighter Bland-Altman limits than LDM. LDM showed larger bias, wider limits, and greater DVH deviations at higher doses, confirming that VSV attains near-MC accuracy with orders-of-magnitude faster computation. Overall, all three methods enable voxel-level dosimetry of 90Y-microsphere therapy, but VSV combines MC-like accuracy with dramatically reduced computation time. VSV thus offers a clinically practical solution for rapid and reliable post-treatment dose verification and may support more personalized treatment evaluation in 90Y radioembolization.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
09:11Y-90 Radioembolization and PD-1 Inhibitor as Neoadjuvant Treatment in Hepatocellular Carcinoma
Published on: May 24, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET