Related Experiment Video
Updated: Jan 20, 2026

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
Robotic-assisted versus fluoroscopy-guided sacroiliac screw fixation: A retrospective comparative study
Maria Auron1, Gal Barkay1, Ohad Einav1
1Department of Orthopedics, Spine Surgery Unit, Hadassah Hebrew University Medical Center, Kalman Yaakov Man St, 9112001 Jerusalem, Israel.
Robotic-assisted sacroiliac (SI) screw fixation shows potential for reduced radiation exposure and improved accuracy in sacral fracture treatment. This technique offers a safe alternative to conventional methods without increasing surgical time.
Area of Science:
- Orthopedic surgery
- Medical robotics
- Trauma care
Background:
- Percutaneous sacroiliac (SI) screw fixation is crucial for sacral fractures but technically challenging.
- Conventional fluoroscopy carries risks of screw misplacement and high radiation exposure.
- Robotic navigation offers enhanced accuracy and reduced radiation for SI screw fixation.
Purpose of the Study:
- To compare the efficiency, safety, and accuracy of robot-assisted SI screw fixation versus conventional freehand techniques.
- To evaluate intraoperative radiation exposure, operative time, screw accuracy, and complications.
Main Methods:
- Retrospective analysis of 25 patients with sacral fractures undergoing SI screw fixation.
- Comparison between a robotic-assisted group (15 patients) and a freehand fluoroscopy-guided group (10 patients).
- Outcomes assessed included radiation dose, operative duration, screw placement accuracy, and complications.
Main Results:
- Operative times were similar between robotic and conventional groups (47.1 vs. 45.1 minutes).
- Robotic assistance trended towards reduced fluoroscopy time (55.1 vs. 181.1 seconds) and improved screw accuracy (94% vs. 62%).
- No major intraoperative complications were reported in either group.
Conclusions:
- Robotic-assisted SI screw fixation may lower radiation exposure and enhance screw accuracy compared to conventional methods.
- The technique appears safe and potentially more precise for sacral fracture fixation.
- Further prospective studies are recommended to confirm the benefits of robotic guidance.
Related Concept Videos
05:57A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
06:24A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
05:42Orthopedic Robot-Assisted Femoral Neck System in the Treatment of Femoral Neck Fracture
08:11A Simple Guide Screw Method for Intracranial Xenograft Studies in Mice
11:28Robotic-Guided Stereoelectroencephalography for Invasive Epilepsy Monitoring