Improved diagnostic performance of CT-derived FFR using 70-keV monoenergetic spectral CT in coronary artery disease
Gylymkhan Bakhjanar1,2, Jung-Joon Cha3, Yu-Whan Oh1
1Department of Radiology, Korea University Anam Hospital, 78, Goryeodae-ro 17ga-gil, Seongbuk-gu, Seoul, 02843, Republic of Korea.
Abstract:
To compare the diagnostic performance of coronary CT-derived fractional flow reserve (CT-FFR) calculated from conventional polychromatic CT images with 70-keV monoenergetic reconstructions derived from spectral CT data. This retrospective study enrolled patients who underwent spectral coronary CT angiography followed by invasive FFR measurements. The CT-FFR values were computed from conventional polychromatic and 70-keV monoenergetic images. Image quality was assessed using the contrast-to-noise ratio (CNR). Comparison of the CT-FFR with invasive FFR provided mean absolute error (MAE), Pearson's correlation, Bland-Altman analysis, and receiver operating characteristic (ROC) curve analysis. Hemodynamically significant stenosis was defined as an invasive FFR < 0.80. Thirty-two patients (21 men, 11 women; mean age, 68.5 ± 8.4 years) with 47 coronary artery lesions were included in this study. The 70-keV images demonstrated significantly higher CNR than conventional images (36.4 ± 15.2 vs. 25.3 ± 7.4; p < 0.01). CT-FFR derived from 70-keV images yielded lower MAE (0.07 ± 0.05 vs. 0.12 ± 0.08; p < 0.01) and showed stronger correlation with invasive FFR (R = 0.769 vs. R = 0.439). Bland-Altman analysis revealed narrower limits of agreement for the 70-keV CT-FFR. In 17 lesions with hemodynamically significant stenosis, the area under the ROC curve of 70-keV CT-FFR was significantly higher than that of conventional CT-FFR (0.929 vs. 0.807; p = 0.01). CT-FFR derived from 70-keV monoenergetic spectral CT images demonstrated promising agreement with invasive FFR and may offer exploratory insight into improving functional assessment of coronary stenosis.
Related Concept Videos
Combined SPECT and CT Imaging to Visualize Cardiac Functionality
Here we will demonstrate the fundamentals of single-photon emission computed tomography/computed tomography (SPECT/CT) imaging using mice. The technique involves injecting a radionuclide into a mouse, imaging the animal after it is distributed throughout the body, and then reconstructing the produced images to create a volumetric dataset. This can...
13:10Direct Re-implantation of Left Coronary Artery into the Aorta in Adults with Anomalous Origin of Left Coronary Artery from the Pulmonary Artery (ALCAPA)
04:37Improved Home Blood Pressure Control by CT-guided Ozone-mediated Renal Denervation for Patients with Resistant Hypertension
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease

