Effect of Thickness and Trim Lines on the Magnitude and Distribution of Transverse Forces Exerted by Thermoformed

Juan Pablo Gómez1, Camila Cuervo2, C A Álvarez3

  • 1INSAO Associate Professor of Biomechanics, Orthodontics Program, Universidad Autónoma de Manizales, Manizales, Colombia.

PubMed
Abstract

Related Concept Videos

Finite Element Analysis Model for Assessing Expansion Patterns from Surgically Assisted Rapid Palatal Expansion07:16

Finite Element Analysis Model for Assessing Expansion Patterns from Surgically Assisted Rapid Palatal Expansion

A set of novel finite element models of surgically assisted rapid palatal expansion (SARPE) that could perform a clinically required amount of expander activation with various angles of buccal osteotomy was created for further analysis of the expansion patterns of the hemimaxillae in all three...
1.8K
Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach08:01

Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach

Methods for designing a computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guide are shown. Cutting planes are separated, united, and thickened to easily visualize the necessary bone transfer. These designs can be three-dimensional printed and checked for...
9.4K
Transverse Aortic Arch Banding in Mouse Model: A Minimally Invasive Technique in Mice for Induction of High Pressure in the Left Ventricle04:38

Transverse Aortic Arch Banding in Mouse Model: A Minimally Invasive Technique in Mice for Induction of High Pressure in the Left Ventricle

In this video, we demonstrate an experimental protocol for minimally invasive transverse aortic constriction in mice to examine pressure overload-induced heart...
3.7K
Trimmed Mean01:10

Trimmed Mean

While measuring the mean of a data set, care needs to be taken when associating the mean to its central tendency. The same goes for the arithmetic mean, the geometric mean, or the harmonic mean. This is because the presence of a single outlier data value can significantly affect the mean. That is, the mean is sensitive to fluctuations in the data set.
Although certain measures of central tendency are not sensitive to outliers, there are alternative versions of the mean that get around the...
3.3K
Traction Cytometry Assay: A Method to Quantify Traction Force Exerted by Cancer Cells on ECM02:44

Traction Cytometry Assay: A Method to Quantify Traction Force Exerted by Cancer Cells on ECM

This video describes the traction force microscopy assay. The assay determines the cellular traction of human colon cancer cells on the extracellular matrix present on soft elastic hydrogel having embedded fluorescent beads. The resultant displacement of fluorescent beads is measured using an appropriate...
1.6K
Minimally Invasive Transverse Aortic Constriction in Mice07:40

Minimally Invasive Transverse Aortic Constriction in Mice

Minimally invasive transverse aortic constriction (MTAC) conserves the essentials of regular transverse aortic constriction (TAC) while eliminating the use of a ventilator with tracheal intubation. It proves to be a highly desirable method for high-throughput studies on left ventricular overload, particularly in translational...
21.5K