Related Experiment Video
Updated: Jan 21, 2026

Assessment of Morphine-induced Hyperalgesia and Analgesic Tolerance in Mice Using Thermal and Mechanical Nociceptive Modalities
Published on: July 29, 2014
Deep learning analysis of particle content in extracted slow-release morphine: longer boiling reduces large fragments
Henrik Sahlin Pettersen1,2, Per Ole M Gundersen3, Trond Oskar Aamo3
1Department of Clinical and Molecular Medicine, The Norwegian University of Science and Technology, Trondheim, NO-7491, Norway. henrik.s.pettersen@ntnu.no.
Introduction:
Injecting drug users often extract morphine from slow-release oral tablets, potentially leading to harmful particle contamination upon injection. This study assesses the efficiency of morphine extraction and particle content of filtrates produced by various methods employed by drug users in Trondheim, Norway. The findings provide important insights that can inform harm-reduction services and healthcare providers in efforts to reduce injection-related morbidity among people who already inject drugs.
Methods:
Four extraction methods were evaluated using 60 mg Dolcontin tablets: Method A (no coating removal, 3-minute boiling), Method B (coating removal, crushing, 3-minute boiling), Method C (coating removal, 3-minute boiling), and Method D (coating removal, 10-minute boiling). Resulting solutions were filtered using cotton balls, and morphine content was quantified using LC-MS/MS. Particle content of filtrates was analyzed using slide scanning, deep learning-based particle segmentation, and QuPath image analysis software.
Results:
Morphine recovery ranged from 81.2% (Method D) to 91.3% (Method B). Method A yielded a significant presence of small insoluble particles (<100 μm), while Method B yielded the highest density of the largest particles (>500 μm). Method C exhibited the highest density of medium-sized particles (100-500 μm). Method D generated the fewest particles across all size categories.
Conclusion:
The extraction methods used by injecting drug users result in significant variability in morphine recovery and particle content of filtrates. Method D (10-minute vs. 3-minute boiling) demonstrated the highest efficiency in particle reduction, with only 10% less morphine recovery. Lack of coat removal significantly increases the number of primarily small (<100 μm) fragments. These findings highlight the importance of evidence-based harm-reduction measures to mitigate risks associated with injecting tablet-derived solutions. The results may support harm-reduction counselling and service design aimed at reducing particulate exposure and related complications, without endorsing or facilitating drug use.
Related Concept Videos
Opioid Analgesics: Morphine and Other Natural Cogeners
Extraction: Effects of pH
Extraction: Advanced Methods
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Extraction: Partition and Distribution Coefficients
For extracting a solute from an aqueous phase into an...
Comparing Intermolecular Forces: Melting Point, Boiling Point, and Miscibility
Temporary attractive forces like dispersion are present in all molecules, whether they are polar or nonpolar. They...