Related Experiment Video
Updated: Jan 22, 2026

A Loop-mediated Isothermal Amplification LAMP Assay for Rapid Identification of Bemisia tabaci
Published on: October 29, 2018
Development and evaluation of loop-mediated isothermal amplification (lamp) for rapid detection of campylobacter
Junior Caro-Castro1, Fiorella Orellana-Peralta2, Diana Flores-León1,3
1Centro Nacional de Salud Pública, Instituto Nacional de Salud, Lima, Perú.
Objectives.:
To develop and evaluate a loop-mediated isothermal amplification (LAMP) assay for the rapid detection of Campylobacter jejuni in stool samples associated with acute diarrheal disease (ADD) and Guillain-Barré syndrome (GBS) for implementation in regional laboratories and primary health care centers.
Materials And Methods.:
Four sets of LAMP primers for C. jejuni were designed and initially evaluated with DNA from C. jejuni, Campylobacter coli, Salmonella Infantis, and Escherichia coli extracted using a commercial kit. The best-performing primer set was selected for assay optimization, determination of the limit of detection, and analytical validation with DNA from the aforementioned strains. Subsequently, clinical validation was performed using stool samples from patients with suspected ADD due to C. jejuni, applying the same standardized conditions used for the strain DNA samples. The sensitivity and specificity of the test were determined using real-time PCR (qPCR) as the standard.
Results.:
The LAMP assay for the detection of C. jejuni in stool samples using a primer set for the cdtC region showed a sensitivity of 97% (CI: 81.49-99.83%), a specificity of 93% (CI: 75.79-98.80%), a positive predictive value of 94% (CI: 77.78-98.91%), and a negative predictive value of 96% (CI: 79.76-99.81%). Furthermore, a strong agreement was demonstrated between this LAMP assay and qPCR (k=0.9).
Conclusions.:
The LAMP assay based on the cdtC gene is a reliable and rapid method, with high sensitivity and specificity comparable to qPCR for the identification of C. jejuni associated with ADD and GBS, especially in low-resource areas, due to its low cost and ease of implementation.
More Related Videos
07:47Reverse Transcription Loop-Mediated Isothermal Amplification RT-LAMP Assay for the Specific and Rapid Detection of Tilapia Lake Virus
Published on: May 18, 2020
06:57Loop-mediated Isothermal Amplification LAMP Assays for the Species-specific Detection of Eimeria that Infect Chickens
Published on: February 20, 2015
Related Concept Videos
RACE - Rapid Amplification of cDNA Ends
Isothermal Processes
An ideal gas can also undergo isothermal expansion or compression.
For example, consider 1 mole of an ideal gas inside an isolated cylinder at initial volume V...
Receptor-mediated Endocytosis
Feedback Loops
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Positive and Negative Feedback Loops