Modified paravertebral foramen screw trajectory for posterior cervical spine fixation: feasibility of computed
Sadaki Mitsuzawa1,2, Eijiro Onishi1, Satoshi Ota1
1Department of Orthopaedic Surgery, Kobe City Medical Center General Hospital, Kobe, Japan.
Study Design:
Retrospective cohort study.
Purpose:
This study aimed to investigate bone quality and the trajectories of modified paravertebral foramen screw (mPVFS) on computed tomography (CT) images compared with those of PVFS and lateral mass screw (LMS).
Overview Of Literature:
With increasing demand for cervical posterior fusion in aging populations, achieving optimal fixation remains challenging. The PVFS offers biomechanical stability with a safer trajectory than traditional pedicle screw and LMS. However, its efficacy in elderly patients with poor bone quality is a concern.
Methods:
We analyzed the cervical CT images of 40 patients (10 patients per group), stratified by age and sex. Bone mineral density was assessed using CT attenuation values of the C5 vertebral body and lateral mass. We compared screw length, insertion area, and CT attenuation values along the screw trajectory across techniques.
Results:
Bone quality decreased significantly with age, particularly in women. The mPVFS had a significantly longer trajectory than that of the PVFS (2.5-3.0 mm longer) and the LMS (1 mm longer) and a larger screw-bone contact area (1.2× that of PVFS, 1.4× that of LMS). CT attenuation values were higher along the mPVFS trajectory than along the PVFS and LMS trajectories. The differences were not consistently significant.
Conclusions:
mPVFS provides a biomechanical advantage by increasing screw length and contact area while targeting dense cancellous bone. mPVFS could safely accommodate screws that are 2.5-3.0 mm longer than conventional PVFS, irrespective of patient age or sex, which may be a potential clinical advantage. To validate its efficacy and long-term stability, further biomechanical and clinical studies are required.
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Carbon-dioxide Fixation
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...