Photon-counting computed tomography: a revolution in cardiac imaging
Gianluca Pontone1,2, Saima Mushtaq1, Carmine Pizzi3,4
1Perioperative Cardiology and Cardiovascular Imaging Department, Centro Cardiologico Monzino IRCCS, Via C. Parea 4, Milan 20138, Italy.
Abstract:
Photon-counting detector computed tomography (PCD-CT) is an emerging advanced CT technology that differs from conventional energy-integrating detector CT (EID-CT) scanners in its ability to directly convert incident X-ray photon energies into electrical signals. Since its commercial market introduction in 2021, several studies have identified advantages of this new technology in the field of cardiovascular imaging, including improved image quality due to an enhanced contrast-to-noise ratio, superior spatial resolution, reduced artefacts, and a reduced radiation dose. Nonetheless, radiation exposure with PCD-CT can vary depending on the acquisition mode and protocol used, highlighting the importance of tailored optimization in clinical practice. In particular, this new technology appears feasible in patients with a high plaque burden independent of morphology, unravelling new phenotypes of plaque, in patients with stents due to the improved visualization of the coronary in-stent lumen, potentially expanding the scope of CT. Early studies and clinical experience support these potential applications of PCD-CT in cardiovascular diagnostics, suggesting workflow optimization and improved patient management. In this review, the authors aim to describe the role of PCD-CT not only in the exclusion of coronary artery disease, grading of coronary stenosis and plaque imaging, but also in evaluation of cardiac chambers and myocardium for tissue characterization trying to understand whether PCD-CT has yet led to a true revolution and significant progress in cardiovascular imaging.
More Related Videos
13:10Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Centroid for the Paraboloid of Revolution
The centroid for the paraboloid of revolution is the point where all the mass of the paraboloid is concentrated. This centroid is important for engineering applications, as it determines how forces are...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Design Example: Traverse Angle Computations
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...