A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Towards robust deep learning-based autosegmentation in MRI-planned gynecological brachytherapy: Importance of
Patricia Jule Oliva1, Shrimanti Ghosh2, Fleur Huang1
1Department of Oncology, University of Alberta, Edmonton, Alberta, Canada.
Purpose:
To present comprehensive development and evaluation methodologies for a generalizable deep learning (DL)-driven autocontouring model of standard pelvic organs-at-risk (OARs) in MRI-planned cervical brachytherapy.
Materials And Methods:
A curated dataset of 200 3D-MRIs (85% training/validation, 15% testing) including multiple applicator types, varying treated anatomies, and manual contours of OARs (bladder, rectum, sigmoid, small bowel) by 3 physicians was utilized to develop an nnU-Net-based autocontouring model. Iterative tuning was conducted to determine the optimal hyperparameters and enhance evaluation metrics. Model performance was assessed using quantitative metrics, like geometric (e.g., Dice Coefficient (DC) and Hausdorff Distance 95th Percentile (HD95)) and dosimetric (dose-volume histograms (DVHs), dose differences (ΔD2cc)), and then correlated with qualitative physician-review (modified Turing and Likert tests).
Results:
Geometric metrics were best for bladder (e.g., mean ± SD DC|HD95(mm) 0.93 ± 0.02|2.26 ± 1.07) with greater variability exhibited for small bowel (0.62 ± 0.16|24.90 ± 14.36). Dosimetric comparisons of manual vs predicted contours showed high agreement in DVHs, with mean ΔD2cc <0.60 Gy EQD23 across all OARs. Model performance was consistent, irrespective of applicator type, OAR volume, or contourer. Quantitative scores in support of DLM were not always associated with as favorable qualitative results, yet physician-review showed clinical acceptability (80% for bladder and rectum).
Conclusion:
The DL-based autocontouring model, trained on a heterogeneous in-house dataset, demonstrates clinical acceptability for OARs as determined by comprehensive evaluation. It also shows promise for translatability to target contouring, and adaptability to other gynecological (noncervix) brachytherapy applications. Differences in qualitative and quantitative results exist; directionality and magnitude should be considered in clinical usability assessments of brachytherapy autocontouring models.
Related Concept Videos
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Planning Nursing Care I
Planning Nursing Care II
Avoidance Learning and Learned Helplessness
Avoidance learning occurs when an organism learns that a specific behavior can prevent an unpleasant outcome. For example, a student who receives a bad grade may start studying harder to avoid future poor grades. This behavior persists even when the negative outcome is no longer present. Avoidance learning is powerful because it maintains behavior in the absence of the...
Learning Disabilities
Dyslexia
Dyslexia is a...
Associative Learning
Classical conditioning, also known...