Ultrasound-based Pulse Wave Velocity Evaluation in Mice
Published on: February 14, 2017
A New Approach to Measure Heart-Carotid Pulse Wave Velocity by Using an Ultrasound-Based Method
Franco Pessana1,2, Ramiro Sanchez3, Agustin Ramirez3
1Department of Information Technology, Engineering and Exact Sciences Faculty, Favaloro University, Buenos Aires, Argentina.
Introduction:
Currently, regional or global assessments of vessel elasticity are performed by measuring pulse wave velocity (PWV) along a long arterial segment. However, this method of evaluating arterial stiffness is subject to bias due to several factors, including the difficulty of accurately measuring the arterial distance. The aim of this research was: (a) to develop a non-invasive method for calculating pulse wave velocity in the heart-carotid pathway (hc-PWV) using electrocardiographic and ultrasonic images; (b) to measure hc-PWV in an adult hypertensive population using this new method and compare the results with values reported in the specialized literature; and (c) to perform a correlation analysis between hc-PWV and heart- femoral pulse wave velocity (hf-PWV) in a population of adult hypertensive subjects.
Methods:
In this study, PWV was calculated using an image analysis technique developed in our laboratory. As an original technique, the theoretical background is first described, followed by its application in hypertensive volunteers. For each subject in the analysed population, the hc-PWV was calculated using the new technique, and the hc-PWV was measured using mechanotransducers.
Results:
in the analysed cohort of hypertensive patients, values of hc-PWV (8.57 ± 0.51 m/s) were similar to those obtained in the carotid-femoral pathway (8.57 ± 0.51 m/s versus 8.19 ± 1.27 m/s; PNS). Moreover, hc-PWV in our cohort of treated hypertensive patients (8.57 ± 0.51 m/s) was higher than that reported by other authors for healthy subjects in similar territories (4.9 ± 1.1 to 8.12 ± 3.54 m/s). Furthermore, the hc-PWV values in our cohort of treated hypertensive patients (8.57 ± 0.51 m/s) were lower than those reported in older subjects with systemic hypertension (11.56 ± 1.74 m/s). A significant correlation was observed between the hc-PWV and cf- PWV (r=0.73, p <0.05). A regression analysis was performed, yielding a slope of 0.2903.
Discussion:
This work showed a novel approach to measuring heart-carotid pulse wave velocity using ultrasound-based methods. In this initial exploration, our aim was not to evaluate or confirm a categorical result, but rather to highlight a trend toward a new methodology for calculating arterial stiffness, contrasted against previously validated standard methods.
Conclusion:
This study confirmed that hc-PWV can be calculated non-invasively using electrocardiographic and ultrasonic images. The calculated hc-PWV values were in the range of those reported in the literature.
Related Concept Videos
Velocity and Acceleration of a Wave
The velocity of the particles can be obtained by taking the partial derivative of the position equation with respect to time....
Special considerations while measuring pulse
Velocity and Position by Integral Method
Consider an example to calculate the velocity and position from the acceleration function. A motorboat is traveling at a constant velocity of 5.0 m/s when it starts to decelerate to arrive at the dock. Its acceleration is...
Velocity and Position by Graphical Method
The Wave Nature of Light
Pulse
The pulse serves as a clinical...