Biotribological Testing and Analysis of Articular Cartilage Sliding against Metal for Implants
Published on: May 14, 2020
Comparison of wear on articular cartilage from polycarbonate-urethane and other implant biomaterials
Maha Ead1, Andrea Dimitrov2,3, Haoyang Li1
1Department of Mechanical Engineering, University of Alberta, Edmonton, Canada.
Abstract:
Talar replacement procedures offer good clinical outcomes for patients experiencing talar osteonecrosis with collapse. However, there is a potential for cartilage wear as the artificial talus prosthesis articulates against the native articular cartilage (AC) in the ankle joint. Therefore, this study investigated the wear of AC against candidate implant biomaterials with the aim of selecting an appropriate material for use in talar replacement procedures. Cobalt chrome alloy (Co-28Cr-6Mo), titanium alloy (Ti-6Al-4V), ultra-high molecular weight polyethylene (UHMWPE), industrial grade natural polyether ether ketone (PEEK), and polycarbonate-urethane (PCU) were tested against porcine AC submerged in bovine serum using an in vitro customized dual-motion wear testing setup. A total of 43,200 cycles at a frequency of 3 Hz were completed for each test. Both macroscopic and microscopic analyses were used to quantify cartilage wear using the Outerbridge and Osteoarthritis Research Society International (OARSI) clinical grading systems, respectively. In the macroscopic analysis, Ti-6Al-4V demonstrated the most AC wear, followed by Co-28Cr-6Mo, PEEK, UHMWPE, and PCU. In the microscopic analysis, PEEK demonstrated the most AC wear, followed by Ti-6Al-4V, Co-28Cr-6Mo, UHMWPE, and PCU. PCU demonstrated the least amount of AC wear compared to all other biomaterials and showed statistically insignificant differences with the control group (porcine cartilage-on-cartilage) in both macroscopic and microscopic inspections. These results suggest that PCU may be a suitable candidate material for coating talus implants as it demonstrated superior AC wear performance compared to the other biomaterials investigated in this study.
More Related Videos
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Growth of Cartilage and Bone Tissue
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits