Related Experiment Video
Updated: Jan 25, 2026

Home-Based Monitor for Gait and Activity Analysis
Published on: August 8, 2019
A wearable monitoring system for running gait analysis by diffusion transformer
Xiaoxue Hu1, Guoyu Wang2, Guodong Ma3
1Department of Leisure Service and Sports, Paichai University, Daejeon, Korea.
Abstract:
Conventional wearable monitoring devices often suffer from insufficient data accuracy and low posture recognition rates, making them inadequate for the demands of professional sports health monitoring. To address these issues, this study proposes a wearable monitoring system for running gait analysis based on the Diffusion Transformer (DiT). The system aims to achieve high-precision running posture recognition and real-time motion monitoring through multi-sensor data fusion and advanced deep learning architecture. First, a wearable system was developed using a nine-axis Micro-Electro-Mechanical System (MEMS) inertial sensor and an UltraWide Band (UWB) positioning module. Data quality was enhanced through sensor calibration, noise compensation, and an adaptive filtering algorithm. Then, a DiT-LSTM running posture recognition model was constructed by integrating the DiT with a Long Short-Term Memory (LSTM) network to perform posture recognition within the wearable system. Experimental results show that on the Human3.6M dataset, the DiT-LSTM model achieved an accuracy of 97.54%, a precision of 97.61%, a recall of 97.73%, an F1-score of 97.58%, and an Area Under the Curve (AUC) of 98.61%. On the HumanEva dataset, the model attained an accuracy of 96.39%, a precision of 96.47%, a recall of 96.8%, an F1-score of 96.92%, and an AUC of 97.9%, all outperforming other algorithms. The complexity assessment showed that DiT-LSTM reached 14.7 GFLOPs on the Human3.6M dataset, with a per-epoch training time of 62.3 seconds, while its per-sample inference latency was only 9.4 ms, meeting real-time monitoring requirements. In the UWB-based position drift correction experiment, Sample 1 achieved mean errors of 0.637 m, 0.581 m, and 0.349 m on the X/Y/Z axes, with corresponding RMSE values of 0.041 m, 0.023 m, and 0.025 m, demonstrating high positioning accuracy and stability. By combining multimodal sensors with the DiT-LSTM model, the study offers reliable technical support for running gait analysis, injury prevention, and personalized training guidance.
Related Concept Videos
Diffusion
Diffusion
Wald-Wolfowitz Runs Test II
For binary data, runs are identified using symbols such as + and −, or equivalently, 1s and 0s. In...
Wald-Wolfowitz Runs Test I
The test works...
Bacterial Transformation
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...
Transformation

