Observational case series on the clinical performance of the Variable Angle Clavicle Plate and Clavicle Hook Plate
Martin Jaeger1, Julia Sußiek2, Frank Beeres3,4
1Albert-Ludwigs-Universität Orthopädie and Traumatologie, Freiburg im Breisgau, Germany.
Background:
Reoperation rates in clavicular fractures and acromioclavicular (AC) joint dislocations are high, often indicated for plate removal due to plate prominence and poor cosmesis. The recently designed 2.7 mm variable angle locking compression plate (VA-LCP®) Clavicle Plate and 2.7 mm VA-LCP® Clavicle Hook Plate (J&J MedTech) are intended to have an improved plate-to-bone fit, are precontoured, and have a low profile. Additionally, the Clavicle Hook Plate has a more anatomically adapted hook design to reduce the risk of painful osteolysis leading to earlier plate removals. All screw holes in these plates accept 2.7 mm screws. Primary objectives of this observational, post-marketing, prospective, multicenter case series are to gather early and mid- to long-term evidence on the clinical performance, safety, and usability of the 2.7 mm VA-LCP Clavicle Plates and 2.7 mm VA-LCP Clavicle Hook Plates, specifically to describe (1) safety, (2) clinical performance, (3) functional outcomes, (4) patient-reported outcomes (PROs) and (5) usability and surgeons' experience with the devices.
Methods:
Approximately 76 patients with clavicle fractures and primary surgical treatment with the 2.7 mm VA-LCP Clavicle Plate or 2.7 mm VA-LCP Clavicle Hook Plate will be enrolled prospectively over 15 months. Outcome measures include adverse events related/potentially related to the investigational device, clinical performance, functional outcomes (QuickDASH), PROs (PROMIS® upper extremity score, local pain, discomfort, and plate prominence), and radiographic outcomes. Data will be collected at baseline, 2w, 6w, 3m, 6m, 1y and 2y after surgery. The surgeons' experience with and perceived utility of the devices will be surveyed. Interim analysis will be performed when 30 patients per group have reached 6 months after surgery. Long-term outcomes will be evaluated using 2-year follow-up results. A Statistical Analysis Plan will be prepared before final analysis summarizing the descriptive statistics to be used.
Discussion:
The study described in this protocol on patients with clavicular fracture or AC joint dislocations undergoing surgical fracture fixation aims to gather first evidence on the clinical performance, safety, and usability of the 2.7 mm VA-LCP Clavicle Plates and 2.7 mm VA-LCP Clavicle Hook Plate Systems. This study will provide valuable data from a standard-of-care setting and may help design future comparative studies for relevant performance parameters.
Clinical Trial Registration:
https://clinicaltrials.gov/study/NCT04921865?term=NCT04921865%20&rank=1, identifier NCT04921865.
Related Concept Videos
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Multi-input and Multi-variable systems
In the absence of...
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Fluid Pressure over Curved Plate of Constant Width
Steady, Laminar Flow Between Parallel Plates