Capture and Detection of Fentanyl with Thiolated Cucurbit[7]uril Macrocycles on Silver Nanoparticles
Adam S Braegelman1,2, Rebekah L Thimes3, Lindy M Sherman3
1University of Notre Dame, Department of Chemical & Biomolecular Engineering, Notre Dame, IN 46556 USA.
Abstract:
Opioid availability and use has expanded in recent years, leading to a dramatic increase in overdose-related deaths and presenting occupational hazards resulting from exposure to fentanyl and related agents. The high potency of fentanyl is especially concerning given it is often added to other illicit drugs of abuse in poorly defined quantities; its presence may furthermore be unknown to the user or other individuals encountering the drug substance. Supramolecular macrocycles from the cucurbit[n]uril family are known to bind fentanyl and related agents. Here, the selectivity of CB[7] to bind fentanyl in solution is demonstrated by competitive NMR studies with 1 mol% fentanyl in complex drug mixtures of either cocaine or diphenhydramine, which are common cutting agents. A thiolated version of the CB[7] macrocycle is also synthesized for the first time, thereby enabling direct attachment of CB[7] to the surface of silver nanoparticles (AgNPs). The ability to modify nanoscale colloids with CB[7] has direct application as capture agents in conjunction with the use of AgNPs for surface-enhanced Raman spectroscopy (SERS). When compared to unmodified CB[7], the thiolated CB[7] offers a significant enhancement in fentanyl detection using AgNPs and SERS, with a limit-of-detection of 0.37 nM. Despite these improvements, non-specific binding of the fentanyl to the AgNPs surface remains, limiting the specificity and selectivity of fentanyl capture in conjunction with SERS detection. However, the binding selectivity of CB[7] towards fentanyl suggests it could be leveraged in the design of nanomaterial sensor platforms for the measurement of fentanyl and related compounds in complex mixtures of illicit drugs.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
![Quantitative SERS Detection of Uric Acid via Formation of Precise Plasmonic Nanojunctions within Aggregates of Gold Nanoparticles and Cucurbit[n]uril](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F61682.jpg&w=3840&q=50)

