Related Experiment Video
Updated: Jan 28, 2026

Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique
Published on: May 3, 2015
Validated LC-MS/MS Method for Vibegron Quantification in Human Plasma via a Selective Fragment Ion (m/z 135.1):
Ashim Kumar Sen1, Santosh Tawari2, Ujashkumar Shah2
1Sumandeep Vidyapeeth Deemed to be University, Vadodara, Gujarat, India.
None:
A sensitive and robust LC-MS/MS method was developed and validated for the quantification of vibegron in human plasma, employing electrospray ionization in positive mode and multiple reaction monitoring (MRM). The precursor ion m/z 445.5 yielded two product ions: m/z 427.4 and m/z 135.1. Despite higher intensity, m/z 427.4 was excluded due to chromatographic interference, while m/z 135.1, previously unreported for vibegron, was selected for its superior selectivity and specificity. A stable isotope-labeled internal standard, vibegron 13C5 (m/z 450.3 → 139.1), was used to enhance precision and minimize matrix effects. Chromatographic separation was achieved on a Kromasil C18 column with a mobile phase of acetonitrile and 10-mM ammonium formate (pH 5.8), yielding a retention time of 1.33 min and total runtime of 3.00 min. Liquid-liquid extraction with ethyl acetate provided consistent recovery (87.7%), and sodium fluoride was added to inhibit enzymatic degradation. The method demonstrated excellent linearity (0.500-400.223 ng/mL), precision (0.58%-3.34%), and accuracy (98.26%-102.29%), using only 100 μL of plasma. Fully compliant with ICH M10 guidelines, the method is well suited for future pharmacokinetic, bioavailability, and bioequivalence studies.
More Related Videos
07:38Functional Characterization of Na+/H+ Exchangers of Intracellular Compartments Using Proton-killing Selection to Express Them at the Plasma Membrane
Published on: March 30, 2015
20:23A Lectin HPLC Method to Enrich Selectively-glycosylated Peptides from Complex Biological Samples
Published on: October 1, 2009
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Habitat Fragmentation
Microtubule Instability
Interference and Diffraction
RNA Interference
This process occurs naturally in cells, often through the activity of genomically-encoded microRNAs. Researchers can take advantage of this mechanism by introducing synthetic RNAs to deactivate specific genes for research or therapeutic purposes. For example, RNAi could be used...
Common Ion Effect