Comparison of two Metop-3MI instrument models and implications for on-ground testing in multi-unit space missions
L Clermont1, C Michel2, Q Chouffart2
1STAR Institute, CSL, Université de Liège, Avenue du Pré-Aily, Liège, 4031, Belgium. lionel.clermont@uliege.be.
None:
Spaceborne optical payloads must undergo extensive on-ground testing before launch, both to verify performance against design expectations and to generate calibration data for in-flight image processing. Stray light, in particular, has emerged as a primary limiting factor requiring precise calibration to enable correction algorithms to reduce it beyond design limits. Recently, a trend has emerged to build multiple units of the same instrument. These payloads can be launched together to increase total field-of-view coverage or consecutively to extend mission lifetime beyond that of a single payload. Because testing requires significant time and resources, this raises a crucial question: should every model undergo full ground testing, or is it sufficient to test just one and apply the findings to all? We address this question by comparing two units of the Metop-3MI Earth-observation instrument, whose demanding performance requirements set particularly stringent needs in stray-light testing. From this comparison we derive testing-strategy guidelines for multi-unit missions, with implications for both institutional programs developing a few identical instruments and New Space ventures aiming to deploy constellations of hundreds.
More Related Videos
07:14Tracking Infiltration Front Depth Using Time-lapse Multi-offset Gathers Collected with Array Antenna Ground Penetrating Radar
Published on: May 1, 2018
12:13Multi-unit Recording Methods to Characterize Neural Activity in the Locust Schistocerca Americana Olfactory Circuits
Published on: January 25, 2013
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Per-Unit Sequence Models
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
Measurement: Standard Units
Measurement: Derived Units
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Taping Over Different Ground Profiles