Tanintorn Pootrakul1, Burana Khiankaew2, Paisarn Boonsakan2
1Saraburi Hospital, Saraburi, Thailand.
Objectives:
Accurate B-lineage assignment in acute leukemia is critical for therapeutic decisions. While nuclear expression of PAX5 protein (nPAX5) is a highly reliable marker for B-cell differentiation, its conventional assessment by time-consuming immunohistochemistry (IHC) is not ideal for rapid diagnosis. This study aimed to validate the utility of flow cytometric (FCM) detection of nPAX5 for the diagnosis of B-lymphoblastic leukemia (B-ALL), potentially enhancing diagnostic efficiency.
Methods:
A retrospective study was conducted, comparing nPAX5 expression by FCM and IHC in 125 bone marrow biopsies (57 B-ALL, 12 T-ALL, 56 AML). Further diagnostic performance analysis, using ROC analysis of the geometric mean fluorescence intensity ratio (Blast/Normal T-cell), was performed for nPAX5, cCD22, and cCD79a across a larger cohort of 538 acute leukemia cases (123 B-ALL, 29 T-ALL, 386 AML).
Results:
FCM and IHC for PAX5 expression showed 100 % concordance across the 125 cases (57/57 B-ALL positive; 0/12 T-ALL negative). The single PAX5-positive AML case harbored the t(8;21) translocation. ROC analysis demonstrated excellent diagnostic performance for both cCD79a (AUC 0.980) and nPAX5 (AUC 0.955). At optimal criteria, cCD79a achieved 100.00 % specificity and 91.06 % sensitivity. nPAX5 showed strong utility, matching the 91.06 % sensitivity with 89.45 % specificity (criterion >6.30). cCD22 exhibited moderate discriminatory power (AUC 0.807).
Conclusions:
Flow cytometric nuclear PAX5 (nPAX5) demonstrated 100 % agreement with IHC and exhibited excellent diagnostic accuracy (AUC 0.955, 91.06 % sensitivity). These compelling results validate nPAX5 as a reliable and powerful FCM marker, supporting its immediate adoption for rapid and efficient B-lineage assignment in acute leukemia diagnostics.
More Related Videos
09:01Flow Cytometry to Estimate Leukemia Stem Cells in Primary Acute Myeloid Leukemia and in Patient-derived-xenografts, at Diagnosis and Follow Up
Published on: March 26, 2018
08:31Murine Model of Leukemia Relapse to Induction Chemotherapy for Acute Lymphoblastic Leukemia
Published on: October 17, 2025
Related Concept Videos
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Diabetes: Symptoms, Diagnosis, and Complications
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
From DNA to Protein