Related Experiment Video
Updated: Jan 28, 2026

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
Published on: October 24, 2018
Polymeric micro- and nanoparticle release from cardiopulmonary bypass and extracorporeal membrane oxygenation
Lars Saemann1, Markus Stiller1, Hardik Vaghasiya2
1Department of Cardiac Surgery, 14942 University Hospital Halle , Halle (Saale), Germany.
Objectives:
Cardiopulmonary bypass (CPB) and extracorporeal membrane oxygenation (ECMO) or life support (ECLS) circuits are built from polymers and might release polymeric micro- and nanoparticles (MNP) into the circulation. MNPs seem to provoke inflammation, oxidative stress, and apoptosis, which are also side effects of extracorporeal circulation. Thus, we investigated the MNP release from CPB and ECMO/ECLS circuits.
Methods:
A CPB and ECMO/ECLS circuit was filled with saline solution, and circulation was initiated for 5 h and 7 d, respectively. Samples were taken from both circuits and filtered through a silicon membrane. MNPs were detected and quantified using optical microscopy and micro Raman spectroscopy.
Results:
During circulation, polyvinyl chloride (PVC) and polymethyl methacrylate (PMMA) were detected in the CPB perfusate. After 5 h of circulation, polyethylene terephthalate (PET) was detected. In the ECMO/ECLS circuit, time-dependent accumulation of polymeric fragments was detected. Finally, particles of polyethylene (PE), polystyrene (PS), PET, and PVC were identified. The particle-size distribution extended from initially <2 µm to finally >10 µm with increasing circulation time.
Conclusions:
CPB and ECMO/ECLS circuits release MNPs. The number of MNPs increases over the period of use. A larger number of circuits and of health effects of identified MNPs, should be investigated.
Related Concept Videos
Energy-releasing Steps of Glycolysis
The first energy-releasing step—the 6th step of glycolysis...
Cardiopulmonary Resuscitation I: Adult
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Second-Order Circuits
Input signals typically originate from voltage or current sources, with the output often representing voltage across the capacitor and/or current through the inductor. For example, in...
Olefin Metathesis Polymerization: Ring-Opening Metathesis Polymerization (ROMP)
Actin Polymerization
The nucleation phase involves forming a stable nucleus consisting of three actin monomers to form a new actin filament. Actin-binding proteins such as formins and Arp2/3 complex help filament growth post-nucleation. The Formins form straight...