Related Experiment Video
Updated: Jan 28, 2026

06:56
Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
Published on: January 7, 2021
2.8K
Effect of magnetic resonance image-based motion correction on the centiloid scale: a comparison with and without
Ryo Yamakuni1, Naoyuki Ukon2, Takashi Kanezawa3
1Department of Radiology and Nuclear Medicine, School of Medicine, Fukushima Medical University, 1 Hikariga-oka, Fukushima, 960-1295, Japan. yamakuni@fmu.ac.jp.
Annals of Nuclear Medicine
|January 27, 2026
Abstract
No abstract available in PubMed .
Related Concept Videos
Distance Corrections
282
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
282
Power Factor Correction
528
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
528
NMR Spectrometers: Resolution and Error Correction
1.1K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
Magnetic Resonance Imaging
9.3K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.3K
Imaging Studies IV: Magnetic Resonance Imaging
270
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
270
Motion Of A Charged Particle In A Magnetic Field
7.0K
A charged particle experiences a force when moving through a magnetic field. Consider the field to be uniform and the charged particle to move perpendicular to it. If the field is in a vacuum, the magnetic field is the dominant factor determining the motion. Since the magnetic force is perpendicular to the direction of motion, a charged particle follows a curved path. The particle continues to follow this curved path until it forms a complete circle. Another way to look at this is that the...
7.0K

