High-resolution Flat-panel Computed Tomography Analysis of Intrascalar Position and Electrode Contact Orientation: A
Ana Marija Sola1, Nicole T Jiam1, Melanie Gilbert1
1Department of Otolaryngology-Head and Neck Surgery, University of California, San Francisco, CA.
High-definition flat-panel CT imaging (FPCT) allows in-vivo mapping of cochlear implant electrode position and orientation. This novel method provides anatomically relevant measurements for improved understanding of electrode placement.
Area of Science:
- Otolaryngology
- Medical Imaging
- Biomedical Engineering
Background:
- Accurate cochlear implant (CI) electrode placement is crucial for hearing outcomes.
- Current methods for assessing intrascalar location and orientation are limited.
Purpose of the Study:
- To present a novel method using in-vivo high-definition flat-panel computed tomographic imaging (FPCT) to determine CI electrode intrascalar location and orientation.
- To establish a model for describing electrode contact directionality.
Main Methods:
- Retrospective analysis of postoperative FPCT scans in adult patients with CIs.
- Utilized mid-modiolar image slices and 3D renderings to measure insertion angle, intrascalar location, and electrode contact orientation.
- Defined electrode contact orientation relative to the modiolus and cochlear partition.
Main Results:
- Average angular insertion depth was 494°.
- Radial distance from the lateral wall to the electrode decreased with depth.
- Basal contacts averaged 59° towards the cochlear partition, while apical contacts averaged 28° towards the modiolus.
Conclusions:
- FPCT enables in-vivo mapping of CI electrode positioning and orientation.
- Measurements align with anatomical expectations and provide a basis for describing electrode directionality.
- Future research will correlate these imaging findings with electrophysiologic and psychophysical outcomes.
More Related Videos
09:35Fabrication of High Contact-Density, Flat-Interface Nerve Electrodes for Recording and Stimulation Applications
Published on: October 4, 2016
11:49Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Wood Panel Products
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Standard Electrode Potentials