Related Experiment Video
Updated: Jan 29, 2026

Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
Published on: May 19, 2023
Comparison of Digital Mammography Plus Full ABUS Review and Digital Mammography Plus Selective ABUS Review Guided by
Inyoung Youn1, Su Min Ha2,3,4, Myoung-Jin Jang5
1Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Objective:
To compare two breast cancer screening strategies, digital mammography (DM) plus radiologist-interpreted automated breast ultrasound (ABUS) and DM plus selective ABUS review, in which only examinations positive for DM or flagged by ABUS artificial intelligence-computer-aided diagnosis (AI-CAD) were reviewed by radiologists.
Materials And Methods:
This retrospective study included asymptomatic women who underwent DM and ABUS screening for breast cancer between March 2022 and March 2023. The radiologists' interpretations of DM and ABUS without AI assistance (DM + ABUS_radiologist) were collected from the clinical radiology reports. A selective DM plus ABUS reading strategy was simulated, in which only cases interpreted as positive in the radiologist's DM report or flagged by retrospectively applied ABUS AI-CAD were triaged for further evaluation through a full review by radiologists (DM + ABUS_AI-CAD). The cancer detection rate (CDR), sensitivity, specificity, and abnormal interpretation rate (AIR) were calculated and compared between DM + ABUS_radiologist and DM + ABUS_AI-CAD groups using the McNemar's test.
Results:
Among 2,275 women (mean age, 56.1 ± 8.6 years), 12 cancers were diagnosed. The sensitivity, CDR and AIR for DM + ABUS_radiologist was 83.3% (10/12; 95% confidence interval [CI]: 51.6-97.9), 4.4 (10/2,275; 95% CI: 2.1-8.1) per 1,000 screening examinations and 16.7% (379/2,275; 95% CI: 15.1-18.3), respectively. DM + ABUS_AI-CAD triaged 84.0% (1,910/2,275) of the examinations as negative in both DM reports and retrospectively applied ABUS AI-CAD, requiring radiologist reassessment in only 16.0% (365/2,275). This approach reduced the AIR to 7.3% (167/2,275) and improved the specificity from 83.7% (1,894/2,263) to 93.1% (2,107/2,263) (all P < 0.001), while maintaining a CDR of 4.8 per 1,000 and a sensitivity of 91.7% (11/12) (all P > 0.999), compared to the DM + ABUS-radiologist.
Conclusion:
An AI-CAD-assisted selective ABUS reading strategy reduces unnecessary recalls and improves specificity, which may help optimize reading priorities and reduce the reading workload while maintaining cancer detection performance.
Related Concept Videos
Drug Abuse and Addiction: Pharmacological Phenomena
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Social Foundations of Self IV: Self in Digital Communication
Intelligence