Comparative Performance of Patch-Type and Lead-Type Wearable Electrocardiogram Devices for Arrhythmia Detection in
Dong Geum Shin1, Bokyoung Kim2, Jihyun Ahn3
1Division of Cardiology, Hallym University Medical Center, Kangnam Sacred Heart Hospital, Seoul 07441, Republic of Korea.
None:
Background/Objectives: Wearable electrocardiogram (ECG) monitoring has become increasingly important in detecting atrial fibrillation (AF) and subclinical arrhythmias by addressing diagnostic gaps inherent to intermittent or asymptomatic presentations. In contemporary clinical practice, two major types of wearable ECG monitors-patch-type and lead-type-are widely used, each with distinct advantages and limitations. This study aims to compare these modalities and evaluate their respective strengths and constraints in real-world settings. Methods: We retrospectively analyzed 639 consecutive outpatients (mean age 61.7 ± 14.5 years; 56.7% male) who underwent wearable ECG monitoring between March 2022 and October 2023. Patients were stratified into patch-type (n = 466; 72.9%) and lead-type (n = 173; 27.1%) groups. Baseline characteristics were comparable. Indications, monitoring duration, arrhythmia detection, and noise rates were assessed. Results: Baseline characteristics did not differ significantly between the two groups. Lead-type monitoring was often prescribed for symptomatic patients (87.9% vs. 75.8%; p = 0.001), Symptomatic patients were older than asymptomatic patients (p = 0.040), whereas the proportion of males was higher in the asymptomatic group (p < 0.001). AF detection rates were comparable between the two groups (24.0% vs. 24.9%; p = 0.911). Patch-type monitoring achieved significantly longer recording duration (p < 0.001) and higher pause event detection (p = 0.004), but at the cost of increased noise burden (p < 0.001). Conclusions: Both patch-type and lead-type wearable ECGs are clinical applicable for arrhythmia surveillance in real-world practice. While AF detection rates were similar, the patch-type monitoring provided more extended observation periods and enhanced pause detection, though accompanied by a higher noise burden. These findings suggest that device selection should be individualized based on patient symptoms, monitoring goals, and tolerability. This study provides practical insights for optimizing wearable ECG use in routine practice.
More Related Videos
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
09:33Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Types of Chemical Bonds
Types of RNA
Three main types of RNA are involved in protein synthesis: messenger RNA (mRNA), transfer RNA (tRNA), and ribosomal RNA (rRNA). These RNAs perform diverse functions and can be broadly classified as protein-coding or non-coding RNA. Non-coding RNAs play important roles in the regulation of gene expression in response to developmental and environmental changes. Non-coding RNAs in prokaryotes can be manipulated to develop more effective antibacterial drugs for human or animal use.
RNA...
Types of Hormones
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay: