Related Experiment Video
Updated: Jan 29, 2026

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Retrospective Analysis of IOL Power Calculation by Ray Tracing in Eyes with Previous Radial Keratotomy
Giacomo Savini1, Kenneth J Hoffer2,3, Arianna Grendele4
1IRCCS Bietti Foundation, 00184 Rome, Italy.
None:
Background/Objectives: To evaluate the predictive accuracy of intraocular lens (IOL) power calculation by ray tracing in eyes with previous radial keratotomy (RK). Methods: A consecutive series of eyes with previous RK was retrospectively analyzed. Preoperatively, all eyes underwent optical biometry to measure the axial length (AL) and anterior segment imaging by the MS-39 (CSO), which combines Placido disk corneal topography and anterior segment optical coherence tomography. The built-in ray tracing software was used to calculate the IOL power. For comparative purposes, the results of the Barrett True-K, EVO, Haigis total keratometry, and PEARL-DGS formulas were also investigated. The refractive outcomes were evaluated with Eyetemis. Results: Twenty-four eyes (24 patients) were investigated. The mean AL and keratometry were, respectively, 27.34 ± 2.88 mm and 35.53 ± 3.66 diopters (D). The mean prediction error (PE) was -0.03 ± 0.65 D (range: from -1.30 to +1.64 D). The mean and median absolute errors were 0.52 and 0.48 D, respectively. The percentages of eyes with a PE within ±0.25 D, ±0.50 D, and ±1.00 D were 29.17%, 62.50%, and 87.50%, respectively. A comparison with the other formulas was possible in 20 eyes and did not reveal any statistically significant differences; the percentage of eyes with a PE within ±0.50 D ranged from 50 to 65%. Conclusions: Ray tracing is a relatively accurate solution for calculating the IOL power in eyes with previous RK. Paraxial formulas provide similar outcomes and should be considered in these patients. The refractive outcomes of IOL power calculation in post-RK eyes are still below modern benchmarks for virgin eyes.
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Calculating the Equilibrium Constant
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
Calculating Standard Free Energy Changes
Calculating pH Changes in a Buffer Solution

