Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Reliability and Validity01:29

Reliability and Validity

13.9K
Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
13.9K
Frictional Forces on Flat Belts01:28

Frictional Forces on Flat Belts

1.4K
Flat belts are commonly used in various industrial applications for transmitting power from one pulley to another. When a flat belt is wrapped around a set of pulleys, it experiences different tensions at the driving pulley ends due to the friction between the belt and pulley surface. When the pulley moves in a counterclockwise direction, the tension T2 on the opposite side of the pulley where the belt is moving away from is higher than the tension T1 on the side where the belt is moving...
1.4K
Flat Belts: Problem Solving01:28

Flat Belts: Problem Solving

809
Flat belts are crucial in many industrial applications as they help transmit power from one pulley to another. The concept of forces and moments is used to determine the maximum moment on a pulley. For instance, consider a flat belt that wraps around two pulleys, A and B, with radii of 30 cm and 10 cm, respectively. The angle between the belt and the horizontal is 20 degrees at the pulleys. As pulley B rotates clockwise and drives pulley A, tension T2 is caused at one end of the belt, while...
809
Physical and Chemical Properties of Matter02:57

Physical and Chemical Properties of Matter

166.1K
The characteristics that enable us to distinguish one substance from another are called properties.
166.1K
Distribution Reliability and Automation01:25

Distribution Reliability and Automation

506
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
506
Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch01:15

Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch

7.5K
The history of therapeutic communication can be traced back to Florence Nightingale, who emphasized the importance of developing trusting relationships with patients. She taught that the presence of nurses with patients results in therapeutic healing.
Therapeutic communication is not the same as social interaction. Social interaction has no goal or purpose and consists of casual information sharing, whereas therapeutic communication has a plan or purpose for the conversation. Therapeutic...
7.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Assessing loading rate in frequency domain by accelerometry.

Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine·2025
Same author

Can Wearable Device Promote Physical Activity and Reduce Pain in People with Chronic Musculoskeletal Conditions?

Journal of clinical medicine·2025
Same author

Change in vaping, smoking and dual-use identities predicts quit success and cigarette usage: A prospective study of people quitting smoking with electronic cigarette support.

British journal of health psychology·2024
Same author

Opposing patterns in self-reported and measured physical activity levels in middle-aged adults.

European journal of ageing·2022
Same author

Morphometric measurements can improve prediction of progressive vertebral deformity following vertebral damage.

European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society·2021
Same author

How Does Obesity Influence the Risk of Vertebral Fracture? Findings From the UK Biobank Participants.

JBMR plus·2020

Related Experiment Video

Updated: Jan 29, 2026

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
08:45

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption

Published on: June 20, 2025

556

Validity and Reliability of Using a Belt-Worn Accelerometer on the Lower Back to Monitor Physical Activity.

Sarah L Williamson1, Jin Luo2, Ian P Albery3

  • 1School of Science, Psychology, Arts and Humanities, Computing, Engineering and Sport, Canterbury Christ Church University, Canterbury CT1 1QU, UK.

Sensors (Basel, Switzerland)
|January 28, 2026
PubMed
Summary

A belt-mounted accelerometer at the lumbar spine accurately measures physical activity. This valid method offers good reliability for long-term studies on rehabilitation and low back pain.

Keywords:
accelerometermeasurementmethodologyphysical activityvalidation study

More Related Videos

Physical Activity Measurement in Children Accepting Table Tennis Training
06:51

Physical Activity Measurement in Children Accepting Table Tennis Training

Published on: July 27, 2022

2.4K
Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity
05:59

Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity

Published on: March 7, 2019

7.1K

Related Experiment Videos

Last Updated: Jan 29, 2026

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
08:45

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption

Published on: June 20, 2025

556
Physical Activity Measurement in Children Accepting Table Tennis Training
06:51

Physical Activity Measurement in Children Accepting Table Tennis Training

Published on: July 27, 2022

2.4K
Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity
05:59

Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity

Published on: March 7, 2019

7.1K

Area of Science:

  • Biomechanics
  • Physical Therapy
  • Wearable Technology

Background:

  • Accurate physical activity measurement is crucial for rehabilitation and low back pain research.
  • Wearable accelerometers are commonly used, but mounting methods require validation.

Purpose of the Study:

  • To evaluate the validity and reliability of a belt-mounted accelerometer for physical activity measurement.
  • To compare belt-mounting with skin-mounting accelerometers at the lumbar spine.
  • To assess the day-to-day reliability of the belt-mounting method.

Main Methods:

  • Two-part study with 10 healthy participants each.
  • Part 1: Compared belt-mounted vs. skin-mounted accelerometers during controlled and free-living activities.
  • Part 2: Assessed day-to-day reliability of each mounting method during controlled exercises.

Main Results:

  • No significant differences in physical activity measurements between belt-mounted and skin-mounted accelerometers.
  • No significant differences in measurements between the two testing days for controlled activities.
  • The belt-mounting method demonstrated good day-to-day reliability.

Conclusions:

  • The belt-mounting method for lumbar spine accelerometers is valid and reliable.
  • This method is suitable for long-term data collection in studies on physical activity, rehabilitation, and low back pain.
  • Supports the use of belt-mounted accelerometers for assessing physical activity impacts.