Related Experiment Video
Updated: Jan 29, 2026

Fabrication of Nanoheight Channels Incorporating Surface Acoustic Wave Actuation via Lithium Niobate for Acoustic Nanofluidics
Published on: February 5, 2020
Mechanisms of Concentric Ring Electrodes in Tuning the Performance of Z-Cut Lithium Niobate Ultrasonic Transducers
Xuesheng Ouyang1, Liang Zhong1,2, Jun Zhou1,2,3
1Key Laboratory of Testing Technology for Manufacturing Process MOE, Southwest University of Science and Technology, Mianyang 621010, China.
Abstract:
Z-cut lithium niobate single crystal demonstrates considerable promise for contact-based ultrasonic nondestructive testing and structural health monitoring (SHM) transducers due to its high piezoelectric coefficients, strong electromechanical coupling capability, and environmentally friendly lead-free composition. As a simulation-based theoretical exploration, this study systematically investigates the impact of gap spacing and electrode width in concentric ring configurations on the resonant characteristics and pulse-echo response of ultrasonic transducers by establishing a parametrized finite element model. Numerical simulations reveal that electrode geometry plays a critical role in determining both the effective electromechanical coupling coefficient and echo signal strength. Optimizing the electrode ring width achieved an effective electromechanical coupling coefficient (keff) of 35.2%, while systematic enlargement of the electrode gap further enhanced this value to 50.8%. The study also demonstrates that optimized ring width and adjusted electrode spacing increased the echo signal's peak-to-peak amplitude (Vpp) by factors of 4.94 and 2.03, respectively, compared to the poorest-performing configuration within each parameter group. This study establishes that precise design of concentric electrode configurations serves as an effective strategy for tuning lithium niobate ultrasonic transducer characteristics, providing critical design guidelines for developing high-performance ultrasonic transducers for solid medium coupling.
Related Concept Videos
Transducer Mechanism: Nuclear Receptors
About 48 different soluble family members of nuclear receptors are identified that can be divided into two main classes:
Transducer Mechanism: G Protein–Coupled Receptors
GPCRs are also called heptahelical,...
Transducer Mechanism: Enzyme-Linked Receptors
Major types that are helpful drug targets include:
Concentration Cells
Consider the following voltaic cell:
Standard Electrode Potentials
Problem-Solving: Tuning of a Guitar String
The string's wave speed can be regulated by varying the linear density. Tension is the other property that determines the speed of...