External Fixation and Adjuvant Pins Versus Volar Locking Plates in Unstable Distal Radius Fractures: A Randomized
John H Williksen1, Audun Tangerud1, Johan C Hellund2
1Division of Orthopaedic Surgery, Oslo University Hospital, Norway.
Purpose:
To investigate if volar locking plates (VLPs) are superior to external fixation (EF) with adjuvant pins in unstable distal radius fractures after 10 years of follow-up.
Methods:
From 2007 to 2009, 111 unstable distal radius fractures were randomized to either EF or VLP. The patients' mean age was 54 years (20-84). At 10 years, 86 patients (77%) were assessed (VLP 43, EF 43). Eighty-one patients (VLP 42, EF 39) had a clinical and radiological examination. Five patients (EF 4, VLP 1) refused to attend the examination, but returned the Disabilities of the Arm, Shoulder, and Hand (QuickDASH) questionnaire. There were 70 women and 16 men with 2 A2, 21 A3, 35 C1, 25 C2, and 3 C3 fractures (AO/ASIF). The patients were assessed clinically by using the visual analog scale pain score at rest/activity, Mayo wrist score, QuickDASH questionnaire, and range of motion. Complications were registered during the study period. The QuickDASH score at 10 years was the primary outcome measure.
Results:
The QuickDASH score was not significantly different between the groups, with a mean score of 9 in the VLP and 10 in the EF. The final QuickDASH scores were lower than the normative values in this age group. There were no clinically relevant differences in the visual analog scale pain score, Mayo wrist score, and range of motion. There was less radial shortening in the VLP group. The C-type fractures demonstrated no significant clinical differences, but there were more cases of radiological osteoarthritis in the EF group. Nineteen patients had their VLPs removed because of hardware problems.
Conclusion:
There were good clinical results in both groups at 10 years, but there is a concern that 19 patients had to have the VLPs removed.
Type Of Study/Level Of Evidence:
Therapeutic I.
Related Concept Videos
Radius of Gyration of an Area
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Euler's Formula for Pin-Ended Columns
To calculate the critical load, envision...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Schwarzschild Radius and Event Horizon
The minimum speed required to launch a projectile from the surface of an object to which it is gravitationally bound so that it eventually escapes the object’s gravitational field is called the escape velocity. The escape velocity is independent of the mass of the object. Merging the idea of escape...