Related Experiment Video
Updated: Jan 31, 2026

Cardiac Magnetic Resonance Imaging at 7 Tesla
Published on: January 6, 2019
Next Generation 7 Tesla Arterial Spin Labeling With Rotated Spiral Acquisition Enables Mesoscale Resolution in 3D
Chenyang Zhao1, Fanhua Guo1, Zidong Yang1
1Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
Purpose:
To achieve high resolution (≤ 1 mm isotropic) whole-brain perfusion imaging at 7 T with next generation ASL pulse sequence, reconstruction algorithm, and MRI hardware.
Methods:
We capitalized on three major innovations: (1) FLASH-based pseudo-Continuous ASL (pCASL) sequence with rotated golden-angle stack-of-spirals (rGA-SoS) sampling; (2) dynamic compressed sensing (CS) reconstruction with high spatiotemporal resolution and motion-resolved self-navigation; and (3) high density array coil and high-performance Impulse gradient of the NexGen 7 T scanner. Whole-brain laminar perfusion imaging was validated by correlation with histological data of microvascular and cell body density, as well as through finger-tapping (FT) and working memory (WM) fMRI tasks.
Results:
The proposed rGA-SoS sequence achieved a 3.3-fold SNR and 2-fold higher intraclass correlation coefficient (ICC) compared to matched Cartesian sampling at 7 T, enabling up to 0.8 mm isotropic spatial resolution and/or a temporal resolution of 14 s at 1 mm isotropic. Resting-state perfusion showed strong correlations with microvascular and cell body density. Laminar perfusion fMRI revealed a two-peak activation in the primary motor cortex induced by FT, and distinct laminar profiles for task-positive and task-negative networks during WM task.
Conclusion:
This method offers a noninvasive imaging tool to bridge the gap between mesoscopic MRI with microscopic cellular imaging, as well as to investigate neural excitation and inhibition underlying positive and negative fMRI activations.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Light Acquisition
NMR Spectroscopy: Spin–Spin Coupling
Spin–Spin Coupling: One-Bond Coupling
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...