Related Experiment Video
Updated: Jan 31, 2026

A Simple and Scalable Fabrication Method for Organic Electronic Devices on Textiles
Published on: March 13, 2017
Mouse model for sensitivity of fluid measurement with textile electrodes
Bryan Piper1,2, Md Saiful Hoque1,2, Nasim Montazeri Ghahjaverestan2,3
1University of Toronto, Toronto, Canada.
None:
Heart failure is a leading cause of morbidity and mortality, and fluid congestion complicates its management. Conventional home-monitoring methods, such as daily weight measurements, are insufficiently sensitive, while invasive techniques are impractical for routine use. This paper introduces a novel, non-invasive approach using textile-based dry electrodes for bio-impedance spectroscopy to detect subtle changes in thoracic fluid volume in a mouse model. Twenty-three mice underwent controlled fluid infusion into the thoracic cavity following a six-stage protocol. Bio-impedance data were collected over 256 frequencies ( kHz) and analyzed to extract and , from which total ( ), extra-cellular ( ), and intra-cellular ( ) fluid volumes were calculated and normalized to baseline. Statistical analyses included two-way ANOVA and multiple linear regression to correlate impedance measurements with animal length and weight. No statistically significant differences in normalized fluid volumes ( , , ) were observed across infusion stages ( ), though there was an anecdotal increase in ( mL) and ( mL) after fluid infusion. Multiple linear regression revealed moderate correlations between impedance measurements and weight ( , , RMSE g) as well as length ( , , RMSE cm). Additionally, a strong correlation was found between length and weight ( , ). The results indicate that textile-based dry electrodes can non-invasively measure thoracic fluid volume in mice, although the sensor's sensitivity to small changes is limited. Further refinement is needed to enhance sensitivity and determine sensitivity threshold. These findings support the continued development of textile-based bio-impedance sensors as a practical tool for non-invasive heart failure monitoring.
Related Concept Videos
The Fluid Mosaic Model
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Standard Electrode Potentials
Fluid Mosaic Model
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...