Related Experiment Video
Updated: Jan 31, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Prognostic Value of Artificial Intelligence-Enabled Electrocardiography-Derived Diastolic Dysfunction Grading and
Chieh-Mei Tsai1, Jwan A Naser1, Gal Tsaban1
1Department of Cardiovascular Medicine Mayo Clinic Rochester Minnesota.
Background:
Artificial intelligence (AI)-enabled electrocardiography has emerged as a tool for detecting cardiac dysfunction. The prognostic relevance of AI-enabled electrocardiography-derived diastolic dysfunction (DD) in patients undergoing transcatheter aortic valve replacement had not been assessed.
Methods:
We analyzed 3197 patients undergoing transcatheter aortic valve replacement for severe aortic stenosis between 2010 and 2023 with baseline 12-lead ECGs processed by a validated AI model to classify diastolic function (grades 0-3). Multivariable Cox models and nested model comparisons assessed associations with all-cause mortality, including a prespecified analysis in patients with indeterminate echocardiographic grading. Trajectories were defined by change in AI-enabled electrocardiography DD grade (<2 versus ≥2) from baseline to 30-day or 1-year follow-up.
Results:
At baseline, 21% had grade 3, 57% had grade 2, 8% had grade 1, and 14% had grade 0 AI-enabled electrocardiography DD. Higher grades were associated with adverse cardiac remodeling and comorbidities. Over a median follow-up of 3.4 years, grade 3 AI-enabled electrocardiography DD independently predicted mortality (hazard ratio [HR], 1.80 [95% CI, 1.47-2.20]; P<0.001). AI-enabled electrocardiography DD improved prognostic discrimination beyond clinical and echocardiographic measures (ΔHarrell concordance statistic, 0.016; Δχ2=57; P<0.001). Among 1259 patients with indeterminate echocardiographic grading, AI-enabled electrocardiography added prognostic value (ΔHarrell concordance statistic, 0.02; Δχ2=13; P=0.006). Worsening or persistently high-risk trajectories were associated with increased mortality (HRs, 1.45-1.80; all P<0.05).
Conclusions:
AI-enabled electrocardiography-derived DD independently predicts mortality after transcatheter aortic valve replacement, adds value beyond echocardiographic grading, and enables dynamic risk stratification through longitudinal tracking.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Orthogonal Trajectories
Intelligence
Graded Potential
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Types of Aggregate Grading
Well-graded aggregates include a complete range of necessary size fractions that fit together to create a dense matrix with minimal voids, represented by a smooth, continuous gradation curve. This type of grading ensures good...
Measures of Intelligence
Validity refers to how well a test measures what it claims to measure. An intelligence test should accurately assess intelligence rather than another characteristic, like anxiety. Criterion validity is one way to evaluate this;...