Related Experiment Video
Updated: Feb 4, 2026

Engineering Platform and Experimental Protocol for Design and Evaluation of a Neurally-controlled Powered Transfemoral Prosthesis
Published on: July 22, 2014
Continuous volitional control of a bionic leg supports diverse walking patterns in both agonist-antagonist muscle
Federica Damonte1,2, Lucas Avanci Gaudio1,2, Jose Gonzalez-Vargas2
1Department of Biomechanical Engineering, University of Twente, Enschede 7522 LW, The Netherlands.
None:
Myoelectric control paradigms have the potential to enable continuous volitional control of bionic limbs in various movement conditions. Although individuals with below knee amputations and an agonist-antagonist muscle interface (AMI) were proven to display a greater degree of continuous volitional control in bionic ankle-foot systems with respect to conventional socket-suspended prosthetic users, it remains unclear how myoelectric interfaces could translate to non-AMI prosthetic users with bone-anchored prostheses (BAP). This preliminary study proposes a human-machine interface (HMI) based on a neuromechanical model to enable volitional, continuous myoelectric control of a bionic leg in AMI and BAP users, walking across various speeds and ground inclinations. Differently from state of the art solutions, the proposed HMI is based on a digital twin of the intact leg, synthesizing the user's phantom limb musculoskeletal function as controlled by muscle activations measured from the residuum. When embedded in a real-time framework, it enabled the participants to achieve volitional modulation of prosthesis peak plantar-dorsiflexion torques timing and amplitude during overground walking at three speeds (between 1.6 and 3.96 km/h), with case studies provided during calf-raises (30, 45, and 60 bpm) and ramp ascent walking (3 and 5% incline). Before prosthesis control tests, the participants underwent a 2-day gait training session. Results showed that all three subjects learned how to alter initial muscle activation patterns so that an average of 87% of peak activation timing fell within target ranges. The proposed neuromechanical modeling technology opens new avenues toward generalizable HMIs for the volitional control of active prostheses beyond set conditions and amputation types.
Related Concept Videos
Muscles that Move the Leg
Anterior Compartment
The quadriceps femoris, the most visible muscle of the anterior compartment, is integral for leg extension and thigh flexion. It is formed by merging four distinct muscles — the vastus lateralis, vastus medialis, vastus intermedius, and rectus femoris. The quadriceps tendon, a shared tendon of the four quadriceps muscles, is affixed...
Muscles of the Leg that Move the Foot and Toes
Anterior Compartment
The anterior compartment includes muscles that contribute to the dorsiflexion of the foot. This compartment houses the tibialis anterior, extensor hallucis longus, and extensor digitorum longus muscles....
Bone as Supporting Connective Tissue
Bone Matrix
Bone, or osseous tissue, is a connective tissue that has a large amount of two different types of matrix material. The organic matrix is similar to the matrix material found in other connective tissues, including some amount of collagen and elastic fibers. This gives strength and flexibility to the tissue. The inorganic matrix consists of mineral salts— mostly calcium salts—...
The Anchoring-and-Adjustment Heuristic
Anchoring Junctions
Lipids as Anchors
The carboxy-terminal of most of the prenylated proteins, such as Ras proteins, contains...