Blood-mimicking dye phantoms for evaluating photoacoustic oximetry accuracy
Yong Zhou1, Zixin Wang2, Keith A Wear1
1Center for Devices and Radiological Health, US Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA.
Abstract:
Many proposed clinical applications of photoacoustic imaging (PAI) rely on relative or absolute measurements of blood oxygen saturation (sO2), and evaluation of oximetry measurement accuracy is crucial for assessing device performance. Available bench test methods use phantoms connected to blood flow circuits with tunable oxygenation, but these methods are complex, costly, and pose biohazard safety risks. To address these issues, we have developed stable and tunable blood-mimicking solutions using binary mixtures of commercially available near-infrared organic dyes (NIR746A and IRA980) to enable non-biological phantom-based PAI oximetry test methods. We used spectrophotometry and a custom PA spectroscopy system to characterize dye extinction and PA response at 750 nm and 850 nm, then formulated various dye recipes mimicking sO2 levels from 40 % to 100 %. We then used a custom PAI system to image breast-mimicking polyacrylamide hydrogel phantoms with embedded tubes injected with static volumes of either dye solutions or bovine blood deoxygenated using sodium dithionite. Phantom testing with dyes produced similar performance metrics to blood, with root-mean-squared difference (RMSD) values between photoacoustic sO2 and reference sO2 of 6-17 % for blood and 4-18 % for dyes, sensitivity (slope of the regression line) ranged from 0.4 to 0.7 for blood and 0.4-0.9 for dyes, and depth-averaged bias ranged from 4 % to 17 % for blood and 3-10 % for dyes. These blood-mimicking dyes may offer a simpler, cheaper, safer, and more stable approach to evaluate PAI oximetry accuracy compared to traditional blood flow phantoms. This tool could facilitate establishment of less burdensome and more reproducible phantom-based PAI test methods, ultimately expediting clinical adoption of PAI technology.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...