Experimental calibration of grating period mismatch in Talbot interferometry for accurate x-ray wavefront and surface
Takahisa Koyama1,2, Takamitsu Saito1, Satsuki Shimizu1
1Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198, Japan.
Abstract:
Thermal deformation of x-ray optical elements, especially the first element exposed to high thermal loads, can significantly degrade the performance of synchrotron radiation beamlines. Accurate wavefront measurement is essential for estimating such deformations and improving optical design. Talbot interferometry, employing phase and absorption gratings to produce moiré fringes, enables wide-field wavefront sensing across areas of several to tens of millimeters. However, mismatches in the designed period ratio between the gratings introduce systematic errors in wavefront curvature estimation and surface profile reconstruction. This study investigates the impact of such period mismatches on wavefront accuracy and presents a practical calibration method. Experiments with both minimally used and long-term exposed gratings show that calibration markedly improves the precision of surface profile measurements, reducing variation by up to 50%. These results emphasize the importance of precise grating period calibration for reliable wavefront and surface figure evaluation, particularly for optics subject to thermal deformation under high-power x-ray irradiation.
Related Concept Videos
Mismatch Repair
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
The Periodic Table
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Periodic Classification of the Elements