Related Experiment Video
Updated: Feb 4, 2026

Technical Applications of Microelectrode Array and Patch Clamp Recordings on Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes
Published on: August 4, 2022
Integrated Electrophysiological and Optical Analysis of Human iPSC-Derived Cardiomyocytes Using Transparent ITO
Seul-Gi Lee1, Shinhye Park1, C-Yoon Kim1
1College of Veterinary Medicine, Konkuk University, Seoul, Korea.
Abstract:
Cardiotoxicity assessment is a crucial step in the drug development process. With growing interest in alternatives to animal testing, preclinical cardiotoxicity evaluation has become increasingly important. Human-induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) offer a physiologically relevant in vitro model for this purpose. As a result, electrophysiological analysis platforms using iPSC-CMs have gained attention. However, conventional microelectrode array (MEA) chips rely on metal electrodes, which are costly and optically opaque. This lack of transparency limits detailed morphological observation of the cells. In this study, we employed an MEA chip incorporating transparent and conductive indium tin oxide (ITO) electrodes to simultaneously monitor both morphological changes and field potential (FP) of iPSC-CMs. iPSC-CMs cultured on ITO chips exhibited stable electrophysiological signals reflecting coupled depolarization and repolarization, along with self-organization. Short-term exposure to ion channel blockers did not induce noticeable morphological alterations; however, dose-dependent changes in FPs were observed. In contrast, treatment with cardiotoxic drugs resulted in morphological damage and reduced cell viability, accompanied by progressive alterations in key FP parameters over the treatment period. These findings demonstrate the potential of ITO-based MEA as next-generation cardiotoxicity evaluation platforms capable of real-time monitoring of both drug-induced electrophysiological responses and optical cellular changes.
More Related Videos
11:13Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs
Published on: May 12, 2017
08:03Hybrid Cell Analysis System to Assess Structural and Contractile Changes of Human iPSC-Derived Cardiomyocytes for Preclinical Cardiac Risk Evaluation
Published on: October 20, 2022
Related Concept Videos
Integration by Parts: Indefinite Integrals
Lipid-derived Compounds in the Human Body
Fat-soluble Vitamins
Fat-soluble vitamins, including vitamins A, D, E, and K, are required in minimal quantities, but their deficiencies can lead to severely abnormal physiological conditions. For example, vitamin A deficiency can cause night blindness, dry skin,...
Integration by Parts: Definite Integrals
Chromatin Immunoprecipitation- ChIP
Types of ChIP
ChIP can be divided into two types - X-ChIP and N-ChIP. X-ChIP involves in vivo cross-linking of histones and regulatory proteins to DNA, fragmenting the DNA by sonication, and isolating the protein-DNA...
The Integrated Rate Law: The Dependence of Concentration on Time
Integrator and Differentiator
An integrator within an op-amp circuit produces an output directly proportional to the integral of the input signal. This is achieved by replacing the feedback resistor in a typical inverting...