Related Experiment Video
Updated: Feb 4, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Reduction of zygomaticomaxillary complex fractures with elevator and modified wire and screw: A case report
Bramasto Purbo Sejati1, Muhammad Fuadi2, Lina Mariana2
1Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Universitas Gadjah Mada Yogyakarta and Temanggung Regional General Hospital, Temanggung, Central Java, Indonesia.
Introduction:
Zygomaticomaxillary complex (ZMC) fractures can lead to significant facial asymmetry due to displacement of the zygomatic bone. Its management is challenging because of the complex 3D structure and difficult surgical access to the ZMC. This case report evaluates the combination of elevator and modified wire and screw technique to treat ZMC fractures displacement with facial asymmetry.
Case Reports:
A 31-year-old male patient was referred to the emergency room with complaints of pain, swelling on the right face, and facial asymmetry after a motorcycle accident. Anamnesis revealed that the patient is not under medication nor has systemic diseases. Physical examination demonstrated facial asymmetry, oedema, raccoon eyes, paraesthesia, and signs consistent with ZMC fracture. The patient underwent a CT scan, and a displaced ZMC fracture was found. The patient underwent ORIF 3-point fixation to stabilize the zygomaticomaxillary complex fractures mechanically. Elevator and modified wire and screw were used to reduce the fractured fragment and restore the anatomical position of the zygoma. Postoperative follow-up demonstrated a restored midfacial symmetry, improved ocular motility, and high patient satisfaction, with minimal complications.
Discussion:
The modified elevator, wire and screw combination technique offers a solution for the management of complex ZMC fractures, especially those involving rotational deformity in medial rotational fractures. The use of screws and wires is effective in cases of ZMC group IV with controlled strength.
Conclusion:
Combination of elevator and modified wire and screw technique is effective in restoring anatomical facial symmetry and functional recovery in the management of ZMC fracture.
More Related Videos
Related Concept Videos
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Oxidation-Reduction Reactions
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Elevation of Intermediate Points on Vertical Curves