Background:
High-flow nasal cannula (HFNC) reduces dead-space ventilation, but this effect is diminished by open-mouth breathing and partial airway obstruction. Consequently, it is uncertain whether HFNC provides respiratory support during endobronchial ultrasound (EBUS) procedures.
Methods:
A single-center randomized controlled crossover study was conducted at the Rijnstate Hospital, Arnhem, the Netherlands, from November 2022 to August 2024.Patients with severe COPD (Gold III/IV) were evaluated to determine if HFNC reduces dead space ventilation during an EBUS procedure. Exclusion criteria were known neurodegenerative conditions, allergies to propofol or esketamine, pregnancy, upper-airway obstructions, or severe pulmonary hypertension.Subjects received two sequences of HFNC flow (30 and 70 L/min or vice versa) during EBUS.The primary outcome was CO2 washout, determined by a 60-s capnography trace with and without HFNC flow to measure the difference in inspiratory, end-tidal CO2, and β-angle.
Results:
Twenty subjects with severe COPD (Gold III/IV) were included (Group A n = 10; Group B n = 10), of which one could not complete the bronchial measurements because of an obstructing carcinoma. CO2 washout at carina was observed at 70 L/min of HFNC flow, demonstrated by a reduced inspiratory CO2 of mean 6.0 mm Hg (95% CI: 4.5-8.3, P < .001) and end-tidal CO2 of 5.3 mm Hg (95% CI: 2.3-7.5, P = .002), but not at 30 L/min of HFNC flow (mean inspiratory CO2 difference of 1.5 mm Hg (95% CI: -2.3 to 6.0, P = .69) and mean end-tidal CO2 difference of 0.8 mm Hg (95% CI: -2.3 to 3.0, P = .35). A flow of 70 L/min reduced inspiratory CO2 in the left main bronchus (mean = 5.3 mm Hg; 95% CI: 2.3-8.3, P < .001), but not the end-tidal CO2 (mean = 3.0 mm Hg; 95% CI: 0.0-6.0, P = .07).
Conclusions:
An HFNC flow of 70 L/min reduced dead-space ventilation in subjects with severe COPD undergoing EBUS procedures during deep sedation, suggesting respiratory support during this procedure.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Requirements for Human Life
Oxygen
Atmospheric air is only about 20 percent oxygen, but that oxygen is a key component of the chemical reactions that keep the body alive, including the reactions that produce ATP. Brain cells are susceptible to a lack of oxygen because they require a...
Nose and Nasal Cavity
Proteins: Dietary Sources and Requirements