Related Experiment Video
Updated: Feb 5, 2026

Advanced Glycation End-Products Sensitize Human Sensory-Like Neuron Cells to Capsaicin-Induced Calcium Influx
Published on: May 2, 2025
Associations between glycated albumin and current measures of glycaemic control in Saudi adults
Suhad Bahijri1,2,3, Aliaa Sabban1,2,3, Sumia Enani2,3,4
1Department of Clinical Biochemistry, Faculty of Medicine, King Abdulaziz University, Jeddah, Saudi Arabia.
Background:
Current dysglycaemia detection methods have limits; glycated albumin (GA), unaffected by conditions that distort HbA1c, is proposed as an alternative. We aimed to estimate the relationship between various glycaemic parameters and their association with GA in Saudi adults to evaluate GA potential utility in screening, detecting, and monitoring diabetes (DM) and intermediate hyperglycaemia (IH).
Method:
A total of 132 biobank serum samples (-80°C) representing a wide glycaemia range, using HbA1c, fasting plasma glucose -FPG, and 1 hour plasma glucose- 1h-PG data. Serum GA was measured by ELISA and expressed as %. Correlations with glycaemic markers were assessed, group means (normoglycaemia, IH, DM) were compared, and diagnostic performance evaluated by ROC analysis. Optimal GA cut-offs for dysglycaemia and DM were determined, with significance set at P< 0.05.
Results:
Used measures of glycaemia did not consistently classify glycaemic status in the same way. The groups with IH and DM had significantly higher mean GA values compared with the normoglycaemia group (P<0.001). GA values correlated significantly with all glycaemic markers (P<0.001), showing the strongest correlation with HbA1c, and the weakest with 1h-PG. the optimal GA cut-off values for detecting dysglycaemia was 13.9% (Sensitivity= 0.786, specificity= 0.917), and 14.7% (Sensitivity= 0.857, specificity= 0.747) for DM.
Conclusion:
GA correlated significantly with other markers and can be suggested as an alternative to detect and monitor glycaemic status among Saudis. Further research is required to determine ranges in our population.
Related Concept Videos
Controlled-Current Coulometry: Overview
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Association Areas of the Cortex
Prefrontal Association Area: This area is located in the frontal lobe and is involved in planning, decision-making, and moderating social behavior. It connects with primary motor areas,...
Associative Learning
Classical conditioning, also known...
Electrical Current
Genome-wide Association Studies-GWAS
GWAS does not require the identification of the target gene involved in...