Related Experiment Video
Updated: Feb 9, 2026

Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Pooled diagnostic accuracy of 68Ga-pentixafor PET/CT for aldosterone-producing lesions in primary aldosteronism
Victor Arthur Ohannesian1, Diego Rajchenberg2, Isabelle R Menezes3
1Department of Medicine, Albert Einstein Israeli Faculty of Health Sciences, São Paulo, São Paulo, Brazil; Department of Radiology and Diagnostic Imaging, Hospital Israelita Albert Einstein (HIAE), São Paulo, São Paulo, Brazil.
Background:
Primary aldosteronism is a leading cause of secondary hypertension and is associated with increased cardiovascular risk. Accurate localization of aldosterone-producing lesions is essential to guide curative treatment. Although adrenal venous sampling (AVS) remains the gold standard for subtyping, it is invasive and not widely available. Recent advances in molecular imaging, including 68Ga-Pentixafor PET/CT targeting CXCR4, have shown potential for non-invasive localization of functional adrenal lesions.
Purpose:
To assess the pooled diagnostic accuracy of 68Ga-Pentixafor PET/CT for detecting aldosterone-producing lesions.
Methods:
A systematic review and meta-analysis were conducted following PRISMA-DTA guidelines. Databases including PubMed, Embase, Scopus, Web of Science, and CENTRAL were searched through January 2025. Eligible studies included adult patients with primary aldosteronism who underwent 68Ga-Pentixafor PET/CT, with reference standards including AVS, histopathology, or immunohistochemistry. Diagnostic accuracy outcomes were pooled using a bivariate random-effects model.
Results:
Eight studies comprising 564 patients were included. Agreement between reviewers during full-text assessment was almost perfect (Cohen's κ = 0.93). Pooled sensitivity was 83% (95% CI: 75-89), specificity 94% (95% CI: 83-98), AUC 0.91 (95% CI: 0.88-0.93), LR+ 14.6 (95% CI: 5.3-40.2), and LR- 0.18 (95% CI: 0.12-0.27). Diagnostic performance remained stable across subgroups, with no significant variation according to tracer dose, SUVmax, acquisition time, study design, or CXCR4/CYP11B2 expression. No evidence of publication bias was detected (Deeks' test, p = 0.93).
Conclusions:
68Ga-Pentixafor PET/CT demonstrates high diagnostic accuracy for identifying aldosterone-producing lesions and may serve as a reliable, non-invasive alternative to AVS in selected patients.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
10:04Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Hormonal Regulation
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...