Related Experiment Video
Updated: Feb 10, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Comparing the express and enhanced workflows for restoration of hip length and combined offset using the Mako robotic
Tim Cheok1,2,3, Veronica Pajnic1, Julie F Vermeir1,4,5
1Department of Orthopaedic Surgery, The Prince Charles Hospital, Brisbane, Australia.
Aims:
The Mako system is one of the most widely used systems for robotic arm-assisted total hip arthroplasty (THA). Two workflows for femoral preparation exists for this system - the enhanced and the express workflow.
Methods:
We performed a retrospective cohort study comparing the accuracy of each workflow in restoring the patient's combined offset and correcting the hip length discrepancy. The Mako derived values were compared against measured values and assessed with Bland-Altman plots and Theil's median slope. Secondary outcomes of interest included comparison of the measured combined offset and hip length discrepancy, surgical time, incidence of postoperative instability/dislocation, as well as pin-site related complications between the two groups.
Results:
A total of 81 patients were identified from our database: 61 in the enhanced group and 20 in the express workflow group. Bland-Altman plots demonstrated agreement between the measurements for both hip length discrepancy and combined offset. There was no significant difference in the measurement of hip length discrepancy or combined offset difference between the two groups; however, the magnitude of the latter was better in the enhanced (median 1.50 mm) compared with the express workflow group (median 3.13 mm). There was no significant difference in measured combined offset (p = 0.254), hip length discrepancy (p = 0.425), or surgical time (p = 0.548). Lastly, there were no patients with postoperative instability/dislocation nor pin-site related complications in either group.
Conclusion:
Both techniques provide excellent outcomes with minimal risk of complications when performing a Mako robotic arm-assisted THA.
Related Concept Videos
Restorative Care
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...
Self-Evaluation: Self-Enhancement and Self-Verification
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Total Voids in Concrete
Comparative Excretory Systems

