Related Experiment Video
Updated: Feb 10, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Central venous pressure, rather than cardiac output, is associated with peripheral chemoreceptor sensitivity in heart
Maksym Jura1, Roman Przybylski2, Piotr Niewiński2
1Institute of Heart Diseases, Wroclaw Medical University, ul. Borowska 213, Wroclaw 50-556, Poland; Department of Physiology and Pathophysiology, Wroclaw Medical University, ul. T. Chałubińskiego 10, Wroclaw 50-368, Poland.
Background:
Heart failure (HF) patients experience elevated sympathetic tone and abnormal peripheral chemoreceptor (PChR) function (elevated sensitivity [PChS] and tonicity [PChT]), which can be attributed to a reduction in cardiac output (CO) and resultant hypoperfusion of the carotid bodies. Left ventricular assist devices (LVADs) are known to increase CO, and can be used as a unique model to examine the impact of acute hemodynamic changes on PChR.
Methods And Results:
Fourteen HF patients with LVADs underwent assessment of PChS (using the transient hypoxia test) and PChT (using low-dose dopamine infusion) under different LVAD flow parameters, previously determined using right heart catheterization to achieve significantly distinct CO levels. PChS did not differ between the low- vs high-flow conditions (0.61 [0.49;0.74] vs. 0.67 [0.33;0.9] L/min/SpO2%, p = 0.36) as well as PChT (0.97 [-0.36;1.96] vs. 0.81 [-1.67;2.2] L/min-1, p = 0.81).). In 9 patients, central venous pressure (CVP) decreased in response to higher pump speeds. In this group, PChS more frequently increased and was significantly higher than in the remaining patients. ΔCVP was also inversely related to ΔHVR (R = 0.75, p = 0.002).
Conclusions:
Acute changes in CO, as well as pulse pressure, did not affect PChS or PChT. Surprisingly, we observed a strong correlation between a decrease in CVP in response to higher LVAD speed and an increase in PChS, which can be explained by the function of low-pressure baroreceptors. These findings provide unique data on PChR function under different hemodynamic conditions in the LVAD population.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Catheterization III: Left Heart Catheterization
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...