Background:
The Alterra Adaptive Prestent provides a landing zone for implantation of the 29 mm SAPIEN 3 transcatheter heart valve (THV) in patients with a dysfunctional right ventricular outflow tract (RVOT) to treat pulmonary regurgitation (PR). Here, we report 3-year outcomes from a pooled analysis of patients who underwent Alterra/SAPIEN 3 THV implantation enrolled in the ALTERRA pivotal trial, Continued Access Protocol, and Pulmonic Delivery System Registry.
Methods:
This multicenter, prospective trial enrolled patients with moderate or greater PR and RVOT/pulmonary valve anatomy suitable for implantation. The nonhierarchical composite end point of THV dysfunction was examined at 6 months: RVOT/pulmonary valve reintervention, moderate or greater PR, and mean RVOT/pulmonary valve gradient ≥35 mm Hg. Individual components of the composite, as well as additional clinical and echocardiographic outcomes were examined up to 3 years.
Results:
The Alterra/SAPIEN 3 THV system was implanted in 118 patients at 14 sites. At 6 months, THV dysfunction was 3.5% (4/113). At 3 years, 97.3% of patients in the valve implant population had freedom from reintervention, 100% of patients had a mean RVOT/pulmonary valve gradients <35 mm Hg, and 93.3% of patients had mild or lesser total PR. The Kaplan-Meier estimate of all-cause mortality was 3.5% at 3 years. There were no cases of coronary artery compression, hemopericardium, or endocarditis.
Conclusions:
This analysis reports the longest follow-up in the largest cohort of patients from the ALTERRA trials. The Alterra Adaptive Prestent with the SAPIEN 3 THV system has shown excellent procedural outcomes and is effective in reducing PR at 3-year follow-up.
Registration:
URL: https://www.clinicaltrials.gov; Unique identifier: NCT03130777.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Anatomy of the Heart
ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH3
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management