Low Revision Rates with Locking Plate Fixation of Proximal Humerus Fractures: A Comparison of Two Implant Systems
Sarah Whitaker1, Yekeen Abu-Shiraz1, Suhas Velichala1
1Virginia Commonwealth University, Department of Orthopaedic Surgery, Richmond, VA, USA.
Abstract:
The purpose of this study was to compare outcomes following open reduction and internal fixation (ORIF) of proximal humerus fractures with Zimmer Biomet and DePuy Synthes plating systems. This was a retrospective review of patients who underwent proximal humerus fracture fixation utilizing Zimmer Biomet or DePuy Synthes plating systems between June 2016 and February 2023. Patients without postoperative follow-up were excluded. Complication rates were compared between the two cohorts using chi-square and two-tailed t-tests for categorical and continuous variables, respectively. A total of 86 patients were identified for inclusion and eight were excluded for inadequate follow up. Statistical analysis comprised a total of 78 patients, 41 who underwent ORIF with a Zimmer Biomet implant, and 37 who underwent ORIF with a DePuy Synthes implant. The overall complication rate was 4.88% (n = 2) in the Zimmer Biomet cohort and 13.5% (n = 5) in the DePuy Synthes cohort (P > 0.05). Both Zimmer Biomet patients required revision surgery, compared with two out of five patients in the DePuy-Synthes group. There were no statistically significant differences in rates of avascular necrosis, impingement, malunion, or fixation failure between the two cohorts. Overall complication rate and need for revision surgery were similar between patients who underwent fixation with the Zimmer Biomet or DePuy Synthes plating systems. Our findings support selection of either plating system based on surgeon preference and equipment availability as neither demonstrated clinical superiority.
More Related Videos
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Bones of the Upper Limb: Humerus
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...