Related Experiment Video
Updated: May 6, 2026

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
The Electrophysiologist's Worst-Case Scenario: Aortic Near-Miss Revealed by Contrast-Enabled Radiofrequency Needle
Jacopo Costantino1, Massimiliano Campoli2, Barbara Romani2
1Department of Cardiology, San Pietro Fatebenefratelli Hospital, Rome, Italy; Department of Medical and Cardiovascular Sciences, Sapienza University of Rome, Rome, Italy; Department of Medicine, University of Padova, Padua, Italy.
Abstract:
A 49-year-old woman undergoing pulsed-field ablation for symptomatic atrial fibrillation experienced a near-miss aortic entry during transseptal access. Despite apparently adequate fluoroscopic positioning, subtly rotated septal anatomy masked an anterior trajectory. Contrast injection through an NRG radiofrequency needle unexpectedly delineated the external aortic root before sheath advancement. Immediate transesophageal echocardiography and subsequent computed tomography confirmed the absence of structural injury. The ablation was safely completed 2 days later. This case illustrates how challenging septal orientation can limit the reliability of fluoroscopic cues, and it highlights the complementary safety value of contrast-capable radiofrequency needles and adjunctive imaging.