Related Experiment Video
Updated: Feb 11, 2026

Author Spotlight: Innovative Technique for Coronary Angiography in Marginal Donors
Published on: July 12, 2024
Clinical feasibility test of 60 kVp double-low-dose coronary CT angiography with a deep learning reconstruction
Xi Wu1, Manman Zhu2, Yixuan Zou2
1Department of Radiology, Hunan Provincial People's Hospital (The First Affiliated Hospital of Hunan Normal University), Changsha, China.
Objectives:
To test the feasibility of 60 kVp double-low-dose coronary CT angiography (CCTA) with a deep learning reconstruction (DLR) algorithm.
Materials And Methods:
Eighty-nine patients (44 females, 59.9 ± 13.2 years, 23.1 ± 3.3 kg/m2) with known or suspected coronary artery disease were prospectively enrolled. Each patient underwent the double-low-dose CCTA (60-kVp, 28 mL contrast at 2.5 mL/s) and was immediately followed by routine-dose CCTA (100-kVp, 44 mL contrast at 4.0 mL/s). Routine-dose data were reconstructed using hybrid iterative reconstruction (RD-HIR), and double-low-dose data were reconstructed using both HIR (LD-HIR) and DLR (LD-DLR). The consistency of both coronary stenosis assessments and CT-derived fractional flow reserve (CT-FFR) values between low-dose and routine-dose images was quantified using receiver operating characteristic analysis at various levels. Segment-level image quality scores (IQS), signal-noise-ratio (SNR), and contrast-noise-ratio (CNR) were compared among three groups.
Results:
Double-low-dose CCTA achieved a significant reduction in both radiation dose (0.60 ± 0.12 mSv vs 4.43 ± 1.42 mSv) and contrast volume compared to routine-dose CCTA. For the per-segment level, LD-DLR showed significantly higher specificity (0.99 vs 0.94), positive predictive value (0.91 vs 0.68), and accuracy (0.98 vs 0.94) for ≥ 50% coronary stenosis compared to LD-HIR. The area under the curve of LD-DLR was significantly higher than LD-HIR for ≥ 50% stenosis at per-segment (0.94 vs 0.92), per-vessel (0.92 vs 0.89), and per-patient (0.92 vs 0.85) levels; and for CT-FFR ≤ 0.80 at per-vessel (0.94 vs 0.74), LAD-vessel (0.94 vs 0.71), and LCX-vessel (0.99 vs 0.67) levels. The IQS, SNR, and CNR of LD-DLR were not inferior to those of RD-HIR in all segments.
Conclusions:
The 60 kVp double-low-dose CCTA with DLR can significantly reduce radiation dose and simultaneously maintain the high consistency of coronary stenosis and CT-FFR assessments with routine-dose CCTA.
Critical Relevance Statement:
The 60 kVp double-low-dose CCTA protocol is feasible with a novel DLR algorithm without compromising the performance of coronary stenosis and CT-FFR assessments.
Key Points:
Is a 60 kVp double-low-dose CCTA protocol with a DLR algorithm feasible for routine clinical application? The 60 kVp CCTA protocol with the DLR algorithm reduced radiation dose by 86.5% and contrast dose by 36.4%. The 60 kVp CCTA with DLR achieved high consistency of coronary stenosis and CT-FFR values with the routine-dose 100 kVp CCTA.
Related Concept Videos
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Coronary Artery Disease III: Clinical Manifestations
Trial and Error and Algorithm
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses